Fluke 1664FC Multifunction Tester, 50 V, 100 V, 250 V, 500 V, 1000 V , Earth Resistance Measurement With BLE, USB
- RS Stock No.:
- 113-5131
- Mfr. Part No.:
- FLK-1664FC UK
- Brand:
- Fluke
Subtotal (1 unit)*
£2,158.00
(exc. VAT)
£2,589.60
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 05 February 2026
Units | Per unit |
|---|---|
| 1 + | £2,158.00 |
*price indicative
Calibration Options:
- Calibration Type:
- RSCAL
- RS Stock No.
- 113-5140
Each
£2,257.00
(exc. VAT)
£2,708.40
(inc. VAT)
- Calibration Type:
- UKAS
- RS Stock No.
- 113-5142
Each
£2,287.00
(exc. VAT)
£2,744.40
(inc. VAT)
- RS Stock No.:
- 113-5131
- Mfr. Part No.:
- FLK-1664FC UK
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Loop Impedance Test Type | Phase to Earth, Phase to Neutral | |
| Automatic RCD Test | Yes | |
| RCD Ramp Test | Yes | |
| Model Number p | 1664FC | |
| Insulation Test Voltage | 50 V, 100 V, 250 V, 500 V, 1000 V | |
| Maximum Voltage Measurement | 500V ac/dc | |
| Test Type | Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity | |
| Earth Resistance Measurement | Yes | |
| Downloadable Data | Yes | |
| Interface Type | BLE, USB | |
| Continuity Test Current | 10mA | |
| RCD Test Type | A/F, AC, B/B+, G, S | |
| Remote Switch Mode | Yes | |
| Test Standards | IEC 60364 | |
| IP Rating | IP40 | |
| Minimum Continuity Resistance | 20Ω | |
| Length | 100mm | |
| Width | 250mm | |
| Voltage Measurement Range | 50 → 1000V | |
| Safety Category Voltage | 300 V, 500 V | |
| Battery Type | AA | |
| Safety Category | CAT III 500 V, CAT IV 300 V | |
| Height | 125mm | |
| Power Source | Battery | |
| Plug Type | UK | |
| Maximum Continuity Resistance | 2000Ω | |
| Dimensions | 100 x 250 x 125mm | |
| Weight | 1.3 (with Battery)kg | |
| Safety Category Level | CAT III, CAT IV | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Loop Impedance Test Type Phase to Earth, Phase to Neutral | ||
Automatic RCD Test Yes | ||
RCD Ramp Test Yes | ||
Model Number p 1664FC | ||
Insulation Test Voltage 50 V, 100 V, 250 V, 500 V, 1000 V | ||
Maximum Voltage Measurement 500V ac/dc | ||
Test Type Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity | ||
Earth Resistance Measurement Yes | ||
Downloadable Data Yes | ||
Interface Type BLE, USB | ||
Continuity Test Current 10mA | ||
RCD Test Type A/F, AC, B/B+, G, S | ||
Remote Switch Mode Yes | ||
Test Standards IEC 60364 | ||
IP Rating IP40 | ||
Minimum Continuity Resistance 20Ω | ||
Length 100mm | ||
Width 250mm | ||
Voltage Measurement Range 50 → 1000V | ||
Safety Category Voltage 300 V, 500 V | ||
Battery Type AA | ||
Safety Category CAT III 500 V, CAT IV 300 V | ||
Height 125mm | ||
Power Source Battery | ||
Plug Type UK | ||
Maximum Continuity Resistance 2000Ω | ||
Dimensions 100 x 250 x 125mm | ||
Weight 1.3 (with Battery)kg | ||
Safety Category Level CAT III, CAT IV | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Fluke 1664 FC Multifunction Installation Testers
Fluke 1664 FC contains the Insulation-PreTest™ safety function (patent pending). This function prevents you from performing tests with appliances that are connected to the system during test, eliminating accidental damage.
With the addition of Fluke Connect, you can now send test results directly to your smartphone. The results can then be transmitted to other members of the team. Data can also be saved to Fluke Cloud™ Storage, reducing the amount of paperwork and possible errors. It is a secure and accurate way to store test data and create test certificates with Fluke DMS (data management software).
Features
Insulation at L-N, N-PE inputs
Automatic test sequence
Continuity at L-N, N-PE inputs
Fluke Connect® compatibility
ShareLive™ Calling
FlukeCloud™ Storage
On/Off switchable auto-start for RCD and looptest
Z max memory
Heavy duty, single input line cord
Standards
Supplied with
IEC 61851-1. The new 6mA testing functionality adds an important feature to our already comprehensive testing solutions for electric vehicle supply equipment (EVSE), making it easier for our customers to perform all necessary tests in one go.
Related links
- Fluke 1664FC Multifunction Tester 100 V 500 V Earth Resistance Measurement With BLE, USB
- Fluke 1664FC Electrical Tester 100 V 500 V Earth Resistance Measurement With BLE, USB
- Fluke 1664FC Multifunction Tester Earth Resistance Measurement With BLE, USB RS Calibration
- Fluke 1664FC Multifunction Tester Earth Resistance Measurement With BLE, USB UKAS Calibration
- Fluke 1664FC Electrical Tester 100 V 500 V Earth Resistance Measurement With BLE, USB UKAS
- Fluke 1664FC Electrical Tester 100 V 500 V Earth Resistance Measurement With BLE, USB RS
- Fluke 1664FC Multifunction Tester Earth Resistance Measurement With BLE, USB
- Fluke 1663 Multifunction Tester 100 V 500 V Earth Resistance Measurement With USB