ABB SMISSLINE TP S400M MCB, 3P, 13A Curve C, 230V AC, 10 kA Breaking Capacity
- RS Stock No.:
- 177-939
- Mfr. Part No.:
- 2CCS573001R0134 S403M-C13
- Brand:
- ABB
Subtotal (1 unit)*
£94.64
(exc. VAT)
£113.57
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 999,999,999 unit(s) shipping from 10 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £94.64 |
*price indicative
- RS Stock No.:
- 177-939
- Mfr. Part No.:
- 2CCS573001R0134 S403M-C13
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 3 | |
| Current Rating | 13A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 230 V, 400V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | SMISSLINE TP | |
| Series | S400M | |
| Circuit Breaker Type | MCB | |
| Length | 91mm | |
| Width | 54mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 82mm | |
| Model Number | S403M-C13 | |
| Application | Commercial, Industrial | |
| Special Features | Overload Protection, Thermal Tripping | |
| Terminal Contact Type | Screw | |
| Reset Actuator Type | Toggle Switch | |
Select all | ||
|---|---|---|
Brand ABB | ||
Number of Poles 3 | ||
Current Rating 13A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 230 V, 400V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range SMISSLINE TP | ||
Series S400M | ||
Circuit Breaker Type MCB | ||
Length 91mm | ||
Width 54mm | ||
Mounting Style DIN Rail Mount | ||
Depth 82mm | ||
Model Number S403M-C13 | ||
Application Commercial, Industrial | ||
Special Features Overload Protection, Thermal Tripping | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- CH
ABB S400M Series MCB, 3 Poles, 13A Current Rating - S403M-C13
This 3-pole miniature circuit breaker is designed to offer precise protection against overloads and short circuits. It features a C-type tripping characteristic, suitable for circuits with high startup currents, and has a breaking capacity of 10 kA for reliable operation in demanding environments.
Features & Benefits
• Provides precise overload and short circuit protection through a thermal element for overloads and a magnetic element for short circuits
• Offers a precise calibration for tripping at specific current levels, ensuring consistent protection tailored to application needs
• Equipped with a handle mechanism that clearly indicates the ON/OFF status, facilitating easy operation and monitoring
• Compact design allows for efficient use of space in electrical panels
• Modular construction enables straightforward integration with other ABB devices, supporting flexible system upgrades
• Offers a precise calibration for tripping at specific current levels, ensuring consistent protection tailored to application needs
• Equipped with a handle mechanism that clearly indicates the ON/OFF status, facilitating easy operation and monitoring
• Compact design allows for efficient use of space in electrical panels
• Modular construction enables straightforward integration with other ABB devices, supporting flexible system upgrades
Applications
• Used in HVAC systems to safeguard circuits controlling heating, ventilation, and air conditioning equipment
• Applied in lighting control panels to protect circuits for high-intensity discharge lamps and LED systems
• Utilised in motor control centres to shield circuits driving pumps, fans, and compressors from electrical faults
• Employed in agricultural machinery distribution boards to ensure dependable protection of circuits for irrigation and processing systems
• Applied in lighting control panels to protect circuits for high-intensity discharge lamps and LED systems
• Utilised in motor control centres to shield circuits driving pumps, fans, and compressors from electrical faults
• Employed in agricultural machinery distribution boards to ensure dependable protection of circuits for irrigation and processing systems
What is the purpose of the thermal element in this product?
The thermal element provides overload protection by heating up and triggering the breaker when the current exceeds a specific threshold
How does the magnetic element contribute to circuit protection?
The magnetic element quickly trips the breaker during a short circuit by responding to high fault currents
Is this product designed to handle high startup currents?
Yes, it is designed to accommodate high startup currents typically associated with inductive loads
Related links
- ABB SMISSLINE TP S400M MCB 13A Curve B 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 13A Curve C 60V DC, 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 13A Curve B 60V DC, 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 2A Curve C 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 20A Curve C 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 8A Curve C 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 25A Curve B 10 kA Breaking Capacity
- ABB SMISSLINE TP S400M MCB 25A Curve C 10 kA Breaking Capacity