NVE IL485WE, Line Transceiver, RS-485, 5 V, 16-Pin SOIC

  • RS Stock No. 148-278
  • Mfr. Part No. IL485WE
  • Brand NVE
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

RS-485 Line Drivers and Receivers, NVE

Isolating RS-485 line transceivers

RS-485 Line Drivers and Receivers

Specifications
Attribute Value
Number of Transmitters 1
Package Type SOIC
Mounting Type Surface Mount
Pin Count 16
Number of Receivers 1
Typical Single Supply Voltage 5 V
Data Rate 35Mbps
Number of Transceivers 1
Interface Standards RS-485
Transmitter Signal Type Differential
Receiver Signal Type Differential
Minimum Operating Temperature -40 °C
Maximum Operating Temperature +85 °C
Length 10.5mm
Number of Receivers per Line 32
Dimensions 10.5 x 7.62 x 2.5mm
Height 2.5mm
Power Supply Type Single
Number of Drivers per Line 32
Width 7.62mm
57 In stock for FREE next working day delivery
Price Each
£ 13.45
(exc. VAT)
£ 16.14
(inc. VAT)
Units
Per unit
1 - 4
£13.45
5 +
£12.79
Packaging Options:
Related Products
The VIPer Plus series of high-voltage converters combine ...
Description:
The VIPer Plus series of high-voltage converters combine an 800V avalanche-rugged MOSFET, that allows ultra-wide range mains voltage input, with a leading-edge PWM controller. VIPer Plus fixed frequency off-line converters enable SMPS designs meeting the most demanding energy saving regulations with enhanced reliability and scalability. It also comes with the ...
The system basis chip (SBC) NCV7450 integrates +5 ...
Description:
The system basis chip (SBC) NCV7450 integrates +5 V / 250 mA LDO with a high−speed CAN transceiver and one high−side driver with diagnostics, directly controlled by dedicated pins. 5 V ±2% / 250 mA LDO, Current Limitation, Output Voltage Monitoring One High−Speed CAN Transceiver, Current Limitation, Reverse Current Protected ...
CAN FD timing specified up to 5 Mbps ...
Description:
CAN FD timing specified up to 5 Mbps VIO pin on NCV7344-3 Version Allowing Direct Interfacing with 3 V to 5 V Microcontrollers Very Low Current Standby Mode with Wake-up via the Bus Low Electromagnetic Emission (EME) and High Electromagnetic Immunity Very Low EME without Common-mode (CM) Choke No Disturbance ...
Linear Technology’s RS485 standards are widely used in ...
Description:
Linear Technology’s RS485 standards are widely used in local networks as well as data transfer over long distances and they are ideal in industrial and commercial applications. The Profibus (Process Field Bus) protocol is carried out for fieldbus solutions in factory and process automation environments. The RS422 standard is similar ...