Honeywell GLA Series Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Housing, 600V ac, 6A
- RS Stock No.:
- 186-8201
- Distrelec Article No.:
- 136-30-805
- Mfr. Part No.:
- GLAC01A1B
- Brand:
- Honeywell
Subtotal (1 unit)*
£203.36
(exc. VAT)
£244.03
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 122 unit(s) ready to ship
- Plus 14 unit(s) ready to ship from another location
- Plus 4 unit(s) shipping from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £203.36 |
*price indicative
- RS Stock No.:
- 186-8201
- Distrelec Article No.:
- 136-30-805
- Mfr. Part No.:
- GLAC01A1B
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| Contact Configuration | DPDT | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Width | 42mm | |
| Depth | 42mm | |
| Length | 145.8mm | |
| Hazardous Area Certification | NO | |
| Operating Force | 0.33Nm | |
| Mounting Orientation | Side | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 15000000Cycles | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
Contact Configuration DPDT | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Width 42mm | ||
Depth 42mm | ||
Length 145.8mm | ||
Hazardous Area Certification NO | ||
Operating Force 0.33Nm | ||
Mounting Orientation Side | ||
Conduit Entry 20 mm | ||
Mechanical Life 15000000Cycles | ||
- COO (Country of Origin):
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, 1 NC/1 NO Contact Configuration - GLAC01A1B
This limit switch is a Compact mechanical position sensor designed for industrial control and automation tasks where precise actuation is required. It operates via a roller lever actuator and provides snap-action electrical changeover contacts suitable for monitoring movement or end-of-travel positions in machinery and equipment. The unit is housed in an electrostatic epoxy-coated zinc enclosure and has ingress protection suitable for demanding work environments.
Features and Benefits:
• Snap-action contacts provide fast, reliable switching response
• 1NC and 1NO contact arrangement allows versatile circuit control
• Rated for 600V AC and 250V DC to handle varied supply voltages
• IP67 protection permits use in dusty and water-exposed locations
• Mechanical life of 15,000,000 operations supports long service cycles
• Operating range from -25 to 85°C maintains function across climates
• 1NC and 1NO contact arrangement allows versatile circuit control
• Rated for 600V AC and 250V DC to handle varied supply voltages
• IP67 protection permits use in dusty and water-exposed locations
• Mechanical life of 15,000,000 operations supports long service cycles
• Operating range from -25 to 85°C maintains function across climates
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for limit sensing on robotic pick-and-place assemblies
• Used with motor starters to detect shaft or cam position
• Can be used for safety interlocks on access panels and guards
• Suitable for automated packaging machinery position feedback
• Ideal for limit sensing on robotic pick-and-place assemblies
• Used with motor starters to detect shaft or cam position
• Can be used for safety interlocks on access panels and guards
• Suitable for automated packaging machinery position feedback
What conduit connection does it accept for cable entry?
The device uses an M20 Terminal entry to accommodate standard conduit fittings.
How is the actuator configured for side installation?
The roller lever is arranged for side mounting, allowing lateral actuation where space constraints exist.
What is the required actuation effort to operate the mechanism?
The actuator operates with an operating torque equivalent to 0.33 Nm, providing defined force for consistent actuation.
Which standards has the product been approved against?
It carries UL, CSA, CE and CCC approvals for use in applicable regulated installations.
Can it be used in certified hazardous-area installations?
It is not certified for hazardous-area classification and should not be specified where certified explosion protection is required.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Related links
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 10 A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 10 A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600 V ac, 10 A