Honeywell Amplified Airflow Sensor, 1000 cm³/s, AWM40000 Series
- RS Stock No.:
- 623-7927
- Mfr. Part No.:
- AWM43300V
- Brand:
- Honeywell
Subtotal (1 unit)*
£185.16
(exc. VAT)
£222.19
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 136 unit(s) ready to ship
- Plus 2 unit(s) shipping from 12 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £185.16 |
*price indicative
- RS Stock No.:
- 623-7927
- Mfr. Part No.:
- AWM43300V
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Media Monitored | Dry Gas | |
| Device Type | Amplified | |
| Maximum Flow Rate | 1000 cm³/s | |
| Supply Voltage | 15 V dc | |
| Pipe Diameter Range | 0.246 in | |
| Maximum Pressure | 150psi | |
| Material | Plastic | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | +85°C | |
| Series | AWM40000 | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Media Monitored Dry Gas | ||
Device Type Amplified | ||
Maximum Flow Rate 1000 cm³/s | ||
Supply Voltage 15 V dc | ||
Pipe Diameter Range 0.246 in | ||
Maximum Pressure 150psi | ||
Material Plastic | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +85°C | ||
Series AWM40000 | ||
Non Compliant
- COO (Country of Origin):
- CN
Amplified Airflow Sensor AWM40000 Series
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
Features and Benefits
Manifold mount/o-ring sealed
Ceramic flow tube (non-outgassing), 0 to 1000 sccm
High common mode pressure (150 psi ceramic flow tube only)
Operating temperature up to 125°C
High stability at null and full scale
Product Application Information
Damper control for heating, ventilation, and air conditioning systems
Gas analysers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anaesthesia control
Gas metering
Gas chromatography
Related links
- Honeywell Amplified Airflow Sensor AWM3000 Series
- Honeywell Amplified Airflow Sensor AWM3000 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell HAF Series Amplified Airflow Sensor for Dry Gas 50 sccm Max