Recom REM3 DC-DC Converter, ±15V dc/ ±100mA Output, 18 → 36 V dc Input, 3W, Through Hole, +105°C Max Temp -40°C
- RS Stock No.:
- 166-6507
- Mfr. Part No.:
- REM3-2415D/A
- Brand:
- Recom
Subtotal (1 tube of 7 units)*
£427.79
(exc. VAT)
£513.35
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 24 December 2025
Tube(s) | Per Tube | Per unit* |
---|---|---|
1 - 4 | £427.79 | £61.113 |
5 - 9 | £414.97 | £59.281 |
10 - 24 | £402.13 | £57.447 |
25 - 49 | £389.29 | £55.613 |
50 + | £376.47 | £53.781 |
*price indicative
- RS Stock No.:
- 166-6507
- Mfr. Part No.:
- REM3-2415D/A
- Brand:
- Recom
Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | ±15V dc | |
Input Voltage Range | 18 → 36 V dc | |
Power Rating | 3W | |
Input Voltage Nominal | 24 V dc | |
Output Current | ±100mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 2 | |
Output Voltage Adjustment Range | ±13.5 V dc, ±16.5V dc | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Width | 20.3mm | |
Depth | 10.4mm | |
Length | 31.8mm | |
Series | REM3 | |
Load Regulation | ±1% | |
Maximum Temperature | +105°C | |
Minimum Temperature | -40°C | |
Efficiency | 86 %, 86.5 % | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A16, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A16, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage ±15V dc | ||
Input Voltage Range 18 → 36 V dc | ||
Power Rating 3W | ||
Input Voltage Nominal 24 V dc | ||
Output Current ±100mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 2 | ||
Output Voltage Adjustment Range ±13.5 V dc, ±16.5V dc | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Width 20.3mm | ||
Depth 10.4mm | ||
Length 31.8mm | ||
Series REM3 | ||
Load Regulation ±1% | ||
Maximum Temperature +105°C | ||
Minimum Temperature -40°C | ||
Efficiency 86 %, 86.5 % | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A16, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A16, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Related links
- Recom REM3 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM3 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C