Recom REM10 DC-DC Converter, 5V dc/ 2A Output, 9 → 18 V dc Input, 10W, Through Hole, +105°C Max Temp -40°C Min
- RS Stock No.:
- 162-2767
- Mfr. Part No.:
- REM10-1205S/A
- Brand:
- Recom
Subtotal (1 tube of 7 units)*
£436.79
(exc. VAT)
£524.15
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 01 December 2025
Tube(s) | Per Tube | Per unit* |
---|---|---|
1 - 4 | £436.79 | £62.399 |
5 - 9 | £423.69 | £60.527 |
10 - 24 | £410.59 | £58.656 |
25 - 49 | £397.48 | £56.783 |
50 + | £384.38 | £54.911 |
*price indicative
- RS Stock No.:
- 162-2767
- Mfr. Part No.:
- REM10-1205S/A
- Brand:
- Recom
Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | 5V dc | |
Input Voltage Range | 9 → 18 V dc | |
Power Rating | 10W | |
Input Voltage Nominal | 12 V dc | |
Output Current | 2A | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Output Voltage Adjustment Range | ±10% | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Depth | 10.4mm | |
Width | 20.3mm | |
Length | 31.8mm | |
Series | REM10 | |
Load Regulation | ±0.2% | |
Minimum Temperature | -40°C | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A31, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A31, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Efficiency | 84 %, 85.5 %, 86.5 % | |
Maximum Temperature | +105°C | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage 5V dc | ||
Input Voltage Range 9 → 18 V dc | ||
Power Rating 10W | ||
Input Voltage Nominal 12 V dc | ||
Output Current 2A | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Output Voltage Adjustment Range ±10% | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Depth 10.4mm | ||
Width 20.3mm | ||
Length 31.8mm | ||
Series REM10 | ||
Load Regulation ±0.2% | ||
Minimum Temperature -40°C | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A31, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A31, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Efficiency 84 %, 85.5 %, 86.5 % | ||
Maximum Temperature +105°C | ||
Related links
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REC10 DC-DC Converter 9 → 18 V dc Input Through Hole, +81°C Max Temp -40°C Min
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp