BEL POWER SOLUTIONS INC RCM150 DC/DC Converter, 12V/, 137.5V Input 12.5 A, 50.4V Input, 70 °C Max Temp -40 °C Min Temp

Bulk discount available

Subtotal (1 unit)*

£375.50

(exc. VAT)

£450.60

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 06 October 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.

Units
Per unit
1 - 4£375.50
5 - 9£356.72
10 - 24£337.95
25 +£319.17

*price indicative

RS Stock No.:
141-8735
Mfr. Part No.:
110RCM150-12DMQF
Brand:
BEL POWER SOLUTIONS INC
Find similar products by selecting one or more attributes.
Select all

Brand

BEL POWER SOLUTIONS INC

Output Voltage 1

12V

Product Type

DC/DC Converter

Maximum Input Voltage

137.5V

Minimum Input Voltage

50.4V

Output Current 1

12.5A

Number of Outputs

5

MTBF

1220000h

Isolation Voltage

4.2kV

Maximum Output Power

150W

Standards/Approvals

UL, EN, IEC, CSA

Width

96mm

Series

RCM150

Length

164.5mm

Depth

36.1mm

Weight

520g

Maximum Operating Temperature

70°C

Minimum Operating Temperature

-40°C

Efficiency

92.5%

Rugged Melcher™ Cassettes style converters, with their one to three fully-isolated and regulated outputs, are well-suited for applications from rail, communications and industrial where tough, reliable power is paramount.

The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries. The output delivers 150 or 300 W at 12 or 24 V. The converters are designed for chassis mounting and exhibit a closed housing. Many options are available, such as an output ORing FET for redundant operation, output voltage adjustment, interruption time of 10 ms (class ST2), shutdown input, and an output voltage monitor controlling a relay (change-over contact)

RoHS lead-free-solder product

2 input voltage ranges, covering all railway batteries

2 output voltages, 12 and 24 V

Closed housing for chassis mounting

Extremely high efficiency and high power density

Low inrush current

3 connectors: Input, output, auxiliary

Overtemperature, overvoltage, overcurrent, and overload

protection

Many options available

Compliant to EN 50155, EN 50121-3-2

Fire and smoke: compliant to to EN 45545 and NFPA 130