Chauvin Arnoux F606 Clamp Meter, 3000A dc, Max Current 2000A ac CAT III 1500V

Subtotal (1 unit)*

£595.03

(exc. VAT)

£714.04

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 24 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£595.03

*price indicative

Calibration Options:

Each

£648.03

(exc. VAT)

£777.64

(inc. VAT)

RS Stock No.:
766-0624
Mfr. Part No.:
P01120966
Brand:
Chauvin Arnoux
Find similar products by selecting one or more attributes.
Select all

Brand

Chauvin Arnoux

Absolute Maximum AC Current Measurement

2000A ac

Absolute Maximum DC Current Measurement

3000A dc

Absolute Maximum AC Voltage Measurement

1200V ac

Absolute Maximum DC Voltage Measurement

1700V dc

Absolute Maximum Resistance Measurement

99.99kΩ

Model Number

F606

AC Current Measurement Resolution

10mA

DC Current Measurement Resolution

10mA

Best DC Current Accuracy

±(1% rdg + 3dgts)

Clamp Meter Type

AC/DC Clamp Meter

Best AC Current Accuracy

±(1% rdg + 3dgts)

Best AC Voltage Accuracy

±(1% rdg + 3dgts)

True RMS

Yes

Best DC Voltage Accuracy

±(1% rdg + 3dgts)

Functions Measured

AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Harmonics, In-Rush Current, Phase rotation, Power, Power Factor, Resistance

Jaw Capacity Busbars

60mm

Length

296mm

Resistance Measurement Resolution

100mΩ

DC Current Measurement Range

0.25 to 3000 A DC

Dimensions

111 x 41 x 296mm

DC Voltage Measurement Resolution

10mV

Minimum Operating Temperature

-20°C

Height

41mm

AC Voltage Measurement Resolution

10mV

AC Current Measurement Range

0.25 to 2000 A AC

AC Voltage Measurement Range

0.15 to 1200 V AC

Maximum Conductor Size

60mm

Battery Life

>350 h

Weight

640g

Safety Category Level

CAT III, CAT IV

Maximum Operating Temperature

+55°C

Safety Category Voltage

CAT III 1500 V, CAT IV 1000V

Battery Type

LR6

Safety Category

CAT III 1500 V, CAT IV 1000V

Best Resistance Measurement Accuracy

±1 % + 5 digits

Display Type

Backlit LCD

Power Source

Battery

Non-Contact Voltage Detector

No

Width

111mm

COO (Country of Origin):
CN

F605 AC/DC TRMS Clampmeter


The F605 clampmeter is designed for the high-power LV market in sectors such as elctrical power distribution, chemical and petrochemical industries, metallurgy, transport
The main applications are maintenance, testing, monitoring, diagnostics, sizing connection
Equipped with a fast 12-bit TRMS digital acquisition system
The large backlit triple display makes it easy to read in all circumstances
Automatic AC/DC detection
W/VA/var and PF power values
THD-f and THD-r
Resistance and audible continuity
Min, Max and Peak± analysis on all functions
Phase rotation
Relative and differential measurements
TrueInrush current measurements
IP54 protection

Clamp multimeter F606


2,000 A TRMS AC+DC multimeter clamp
With protection against electric shocks up to 12 kV, the F600 Series fulfils the most demanding safety criteria (CAT IV 1,000 V) and offers a high protection rating allowing users to work in total safety on all LV installations.
The F600 Series is ideal for high-power applications such as electrical power distribution, chemical and petrochemical industries, metallurgy, rail transport, etc.

Equipped with a fast 12-bit TRMS digital acquisition system, F606 clamps offer particularly accurate measurements whatever the signal's waveform.

Specifications:


• Clamping diameter: 60 mm
• Current: 2,000 A AC / 3,000 A DC
• Voltage up to 1,200 VAC / 1,700 VDC
• Resistance and audible continuity
• Power values (W, var, VA, PF) and harmonics (THDf, THDr)
• "2-wire method" phase rotation
• Automatic AC/DC detection
• TrueInrush current measurement
• Min, MAX, Peak+, Peak-
• RELative (ΔX) and differential (ΔX/X) measurements
• CAT IV 1,000 V / CAT III 1,500 V
• IP54 protection rating