Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland, M16 x 1.5 Thread, 4.5 mm min., 10 mm max., IP68, IP69
- RS Stock No.:
- 400-123
- Mfr. Part No.:
- 53112010LF
- Brand:
- Lapp
Subtotal (1 bag of 5 units)*
£52.13
(exc. VAT)
£62.56
(inc. VAT)
FREE delivery for orders over £60.00
Temporarily out of stock
- 12 unit(s) shipping from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Bag(s) | Per Bag | Per unit* |
|---|---|---|
| 1 + | £52.13 | £10.426 |
*price indicative
- RS Stock No.:
- 400-123
- Mfr. Part No.:
- 53112010LF
- Brand:
- Lapp
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Lapp | |
| Thread Size | M16 x 1.5 | |
| Product Type | Cable Gland | |
| Maximum Cable Diameter | 10mm | |
| Minimum Cable Diameter | 4.5mm | |
| Material | Nickel Plated Brass | |
| Colour | Nickel | |
| Series | SKINTOP MS-M | |
| IP Rating | IP68, IP69 | |
| Hazardous Area Certification | NO | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 100°C | |
| Standards/Approvals | DIN EN 60423, DIN IEC 62444, DNV, UL, VDE | |
| Select all | ||
|---|---|---|
Brand Lapp | ||
Thread Size M16 x 1.5 | ||
Product Type Cable Gland | ||
Maximum Cable Diameter 10mm | ||
Minimum Cable Diameter 4.5mm | ||
Material Nickel Plated Brass | ||
Colour Nickel | ||
Series SKINTOP MS-M | ||
IP Rating IP68, IP69 | ||
Hazardous Area Certification NO | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 100°C | ||
Standards/Approvals DIN EN 60423, DIN IEC 62444, DNV, UL, VDE | ||
- COO (Country of Origin):
- DE
LAPP SKINTOP MS-M Series Cable Gland, M16 x 1.5 Thread size, Nickel - 53112010LF
This cable gland provides secure cable entry and environmental protection for industrial installations. Manufactured in nickel-plated brass, it is designed for use where resistant metallic fittings are required and where exposure to demanding conditions is expected. The gland accommodates round sheathed cables and is suitable for threaded panel or enclosure installation in automation and electrical systems.
Features and Benefits:
• IP66/IP68/IP69 protection for prolonged harsh-environment performance
• Nickel-plated brass construction offering corrosion resistance and conductivity
• Operating range -40°C to 100°C for varied thermal environments
• Accepts cable diameters from 4.5mm to 10mm for flexible cable selection
• Thread form M16 x 1.5 enabling standard metric panel interfaces
• Conforms to DIN EN 60423 and DIN IEC 62444 for recognised interchangeability
• Nickel-plated brass construction offering corrosion resistance and conductivity
• Operating range -40°C to 100°C for varied thermal environments
• Accepts cable diameters from 4.5mm to 10mm for flexible cable selection
• Thread form M16 x 1.5 enabling standard metric panel interfaces
• Conforms to DIN EN 60423 and DIN IEC 62444 for recognised interchangeability
Applications
• Suitable for control-cabinet cable entries in automation systems
• Ideal for marine installations requiring DNV-classified components
• Used with field instrumentation in harsh outdoor environments
• Can be used for electrical assemblies needing VDE and UL recognised fittings
• Used for machinery wiring where elevated temperature tolerance is essential
• Ideal for marine installations requiring DNV-classified components
• Used with field instrumentation in harsh outdoor environments
• Can be used for electrical assemblies needing VDE and UL recognised fittings
• Used for machinery wiring where elevated temperature tolerance is essential
What thread type is required for panel cut-outs?
The gland uses an M16 x 1.5 threaded connection, matching standard metric tapped holes and locknut fittings.
How does the material affect electromagnetic or grounding requirements?
The metallic nickel-plated brass body provides conductive continuity suitable for bonding practices and earthing when fitted correctly.
Which approvals ensure suitability for safety-conscious installations?
It meets recognised standards including UL and VDE and is certified to DIN EN 60423 and DIN IEC 62444 for dimensional and performance criteria.
Can it withstand cleaning with high-pressure water or steam?
The IP69 rating indicates resistance to high-pressure, high-temperature washdown procedures typical in industrial cleaning.
What cable size range will this fit without additional seals?
The gland is specified for cables with diameters between 4.5mm and 10 mm, allowing direct sealing across that span.
Related links
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 4.5 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 7 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 3.5 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 9 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 19 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 27 mm min. IP68, IP69
- Lapp SKINTOP MS-M Series Nickel Nickel Plated Brass Cable Gland 11 mm min. IP69, IP68
- Lapp SKINTOP MS-SC Series Nickel Nickel Plated Brass Cable Gland 19 mm min. IP68, IP69