Data Loggers

A data logger is a compact, battery powered device equipped with an internal microprocessor, data storage and one or more sensors. They can be deployed in a variety of environments to record measurements at set intervals. The devices automatically monitor and record environmental parameters over time, allowing conditions to be measured, documented, analysed and validated. The data logger contains a sensor to receive the information and a computer chip to store it. Then the information stored in the data logger is transferred to a computer for analysis.

Depending on the particular data logger, measurements can include air temperature, relative humidity, AC/DC current and voltage, differential pressure, time-of-use (lights, motors, etc.), light intensity, water temperature, water level, dissolved oxygen, soil moisture, rainfall, wind speed and direction, leaf wetness, pulse signals, room occupancy, plug load, and many more.
Why would you use a data logger?

Data logging is the collection of data over a period of time, and is something often used in scientific experiments. Data logging systems typically monitor a process using sensors linked to a computer. Most data logging can be done automatically under computer control.

Sensors have an important role in the data logging process. All physical properties can be measured with sensors such as light, heat, sound, pressure, acidity and humidity.
The sensors send signals to an interface box, which is linked to a computer. The interface box converts analogue signals to digital signals that the computer can understand.
The computer controlling the process will take readings at regular intervals. The time interval for data logging is the time between readings. The logging period is the total length of time over which readings are taken.
The readings are stored in tables and can be displayed in graphs or passed to an application for analysis.
Sometimes it is necessary to record data 'out in the field'. This is called remote data logging. Readings are stored and brought back to a computer where they are downloaded and analysed. The equipment in these situations needs to be very robust. For example equipment used to monitor water levels would have to be waterproof and equipment working in a satellite would have to be able to withstand vibration during launch and recovery.

How do you use a Data Logger?
● Download and install software on mobile device or laptop
● Connect to data logger and launch parameters
● Place in location and record data for desired period of time
● Reconnect to data logger via mobile device or laptop
● Download data file and readout with analysis software

...
Read more Read less

Filters

Viewing 41 - 60 of 219 products
Results per page
Description Price Measurement Parameters Sensor Type Number of Input Channels Interface Type Maximum Voltage Measurement Maximum Temperature Measurement Power Source Best Temperature Measurement Accuracy Calibrated IP Rating Minimum Operating Temperature Maximum Operating Temperature Maximum Current Measurement Display Type
RS Stock No. 666-8163
Mfr. Part No.PP549
£185.00
Each
Units
Voltage - 16 USB 2.0 2.5V - Mains - - - 0°C +70°C - -
RS Stock No. 778-2699
Mfr. Part No.PEL 103
£1,382.00
Each
Units
Current, Energy, Frequency, Harmonics, Power, Voltage Current Sensor 6 Bluetooth, Ethernet, USB 1000V ac/dc - Mains - RSCAL IP54 - - 5 A ac, 10 kA ac, 100 A ac/dc, 120 A ac, 240 A ac, 1000 A ac, 1200 A ac, 1400 A dc LCD
RS Stock No. 778-1034
Mfr. Part No.P01157153
£1,290.00
Each
Units
Current, Energy, Frequency, Harmonics, Power, Voltage Current Sensor 3, 4 Bluetooth, Ethernet, USB 1000V ac/dc - Mains - - IP54 0°C +50°C 5000 A dc, 10000 A ac LCD
RS Stock No. 734-9731
Mfr. Part No.EL-USB-2-LCD+
BrandLascar
£78.95
Each
Units
Dew Point, Humidity, Temperature Dew Point, Humidity, Temperature - USB - +80 °C Battery ± 0.45 °C - IP67 -35°C +80°C - LCD
RS Stock No. 756-7327
Mfr. Part No.EL-USB-ACT
BrandLascar
£104.95
Each
Units
Current, Power, Voltage Current Sensor - USB 707 mV ac, 1000 mV dc - Battery - - - -30°C +50°C - LCD
RS Stock No. 717-4038
Mfr. Part No.PT-104
£459.00
Each
Units
Resistance, Temperature, Voltage PT1000 4 Ethernet, USB 2.5 V, 115 mV +800 °C Mains ±0.01 °C - - 0°C +70°C - -
RS Stock No. 666-8154
Mfr. Part No.PP548
£129.00
Each
Units
Voltage - 12 USB 2.0 2.5V - Mains - - - 0°C +70°C - -
RS Stock No. 712-5471
Mfr. Part No.0572 0566
BrandTesto
£119.20
Each
Units
Humidity, Temperature Capacitive, NTC 2 USB - +70 °C Battery ±0.5 °C - IP20 -20°C +70°C - LCD
RS Stock No. 739-8607
Mfr. Part No.PP803
£399.00
Each
Units
Current, Voltage - 3 Ethernet, USB 1V ac - Mains - - - 0°C +50°C 200A -
RS Stock No. 656-0924
Mfr. Part No.TK-4023-PK-RS
BrandGemini
£79.19
Each
Units
Temperature NTC 1 Serial, USB - +125 °C Battery ±0.4 °C - IP30 -40°C +85°C - -
RS Stock No. 126-717
Mfr. Part No.EL-USB-TC
BrandLascar
£54.95
Each
Units
Temperature J, K, T - USB - +1190 (J) °C, +1350 (K) °C, +390 (T) °C Battery ±1 °C - - -10°C +40°C - -
RS Stock No. 749-1914
Mfr. Part No.PP706
£95.00
Each
Units
Digital I/O, Light, pH, Pulse, Resistance, Sound - 14 USB 2.0 5V +70 °C Mains ± 2 °C - - - - - -
RS Stock No. 536-8834
Mfr. Part No.ADC-24 & TERM
£479.00
Each
Units
Voltage - 4, 8 USB 1.1, USB 2.0 ±2500mV - Mains - - - 0°C +45°C - -
RS Stock No. 509-6983
Mfr. Part No.TGP-4500
BrandGemini
£168.75
Each
Units
Humidity, Temperature Capacitive, NTC 2 Serial, USB - +85 °C Battery ±0.6 °C - IP68 -40°C +85°C - -
RS Stock No. 126-723
Mfr. Part No.EL-USB-RT
BrandLascar
£44.95
Each
Units
Dew Point, Humidity, Temperature - - USB - +60 °C Mains ±1.5 °C - - -10°C +60°C - -
RS Stock No. 666-8160
Mfr. Part No.EL-USB-TC-LCD
BrandLascar
£74.95
Each
Units
Temperature J, K, T - USB - +1190 (J) °C, +1350 (K) °C, +390 (T) °C Battery ±1 °C - - -200°C +1350°C - LCD
RS Stock No. 666-8166
Mfr. Part No.EL-USB-2+
BrandLascar
£63.95
Each
Units
Dew Point, Humidity, Temperature - - USB - +80 °C Battery ± 0.45 °C - IP67 -35°C +80°C - -
RS Stock No. 509-6898
Mfr. Part No.TGU-4017
BrandGemini
£78.07
Each
Units
Temperature NTC 2 Serial, USB - +85 °C Battery ±0.6 °C - IP54 -40°C +85°C - -
RS Stock No. 911-9481
Mfr. Part No.0572 1764
BrandTesto
£374.30
Each
Units
Temperature J, K, T 4 USB - +1000 (K) °C, +400 (T) °C, +750 (J) °C Battery ±1 % UKAS IP54 -20°C +70°C - LCD
RS Stock No. 732-0588
Mfr. Part No.0572 1764
BrandTesto
£299.30
Each
Units
Temperature J, K, T 4 USB - +1000 (K) °C, +400 (T) °C, +750 (J) °C Battery ±1 % - IP54 -20°C +70°C - LCD
Related Products
Measures temperature (-10 °C → +60 °C), humidity ...
Description:
Measures temperature (-10 °C → +60 °C), humidity (0 → 100%) and calculates dewpoint in real-time Compatible with 32-bit versions of Windows XP, Vista and 7 Export to Excel functionalityPowered by the USB port - simple interface for set up and data download Once plugged into the PC, the software ...
Tinytag View 2 loggers are equipped with an ...
Description:
Tinytag View 2 loggers are equipped with an LCD display to provide instant indication of temperature, humidity and alarm conditions. The loggers are made with food grade materials and are ideal for use in food processing, retail, fridges and chill cabinet applications. LCD display30000 reading capacity, 30000 for single channel, ...
L452 2-channel data logger is ideal for your ...
Description:
L452 2-channel data logger is ideal for your industrial process applications, such as measurement, dosing or environmental monitoring. The L452 is equipped with 2 inputs. It allows you to connect various types of sensors to the input to record varied data, 4 mA → 20 mA modules and 0 V ...
Temperature and humidity data loggers which are ideal ...
Description:
Temperature and humidity data loggers which are ideal for the monitoring of indoor environmental conditions. Single and dual channel temperature and humidity recorders16000 readingsUser programmable logging intervals from 1s to 10 daysDelayed and triggered start options3 stop options – stop when full, wrap around and stop after n readingsDust and ...