| Phoenix Contact | Redundancy Module | Parallel Connection of Two Power Supply Unit | UNO-DIODE/5-24DC/2X10/1X20 | 4.5 → 30V dc | - | EMC | 20A | Screw | - | - | - | - |
|
| Phoenix Contact | Diode Module | Parallel Connection of Two Power Supply Unit | TRIO2-DIODE/12-24DC/2X10/1X20 | 10 → 30V dc | 0.5V | EMC | - | Screw | - | - | - | - |
|
| Phoenix Contact | Redundancy Module | STEP 3 Power Supplies | STEP3-DIODE/5-24DC/2X5/1X10/PT | 5 → 24V dc | 5 → 24V dc | - | 10 or 2x5A | - | - | EAC Certified, IECEE CB Scheme Certified | - | - |
|
| Phoenix Contact | Battery Module | - | QUINT POWER | 24V dc | 24V dc | - | 50A | - | - | cULus, RoHS Compliant | - | - |
|
| Phoenix Contact | Redundancy Module | DIN Rail Unit | - | 18 → 28V dc | - | - | 20 (Redundancy) A, 40 (Increasing Power) A | - | - | EN 61000-6-2, EN 61000-6-3 | - | - |
|
| Phoenix Contact | Capacity Module | - | QUINT4 | - | - | - | - | - | - | - | - | - |
|
| Phoenix Contact | - | - | STEP POWER | 18.5V dc | - | - | - | - | - | - | - | - |
|
| Phoenix Contact | - | - | QUINT POWER | 24V dc | - | - | 40A | - | Shock Current Protection | cUL, cULus, UL, UL 508, UL 60950 | - | - |
|
| Phoenix Contact | Battery Module | - | UPS-BAT/PB/24DC/1.2AH | 24V dc | 24V dc | - | 15A | - | - | EAC Certified, IECEE CB Scheme Certified | - | - |
|
| Phoenix Contact | Battery Module | - | VRLA-AGM | - | - | - | - | - | - | - | - | - |
|
| Phoenix Contact | Redundancy Module | QUINT POWER Power Supply | QUINT4-S-ORING/12-24DC/1X40 | - | - | EMC | - | Screw | - | - | - | - |
|
| Phoenix Contact | - | Communication Between Higher-Level Controllers and Uninterruptible Power Supply Units, Communication Between Industrial PC and Phoenix Contact Device | - | - | - | - | - | - | - | - | - | - |
|
| Phoenix Contact | Battery | QUINT - UPS - IQ | - | 24V dc | 24V dc | - | 50A | - | - | cULus, RoHS Compliant | - | - |
|
| Phoenix Contact | Redundancy Module | - | QUINT-ORING/24DC/2X40/1X80 | 18V dc | 24V dc | - | 80A | - | - | CE EN61000-6-3, cUL, EMC Directive 2014/30/EU, EN 50178/VDE 0160 (PELV), EN 60950-1/VDE 0805 (SELV), EN 61000-4-2, EN 61000-4-3, EN 61000-4-4EN 61000-4-5, EN 61000-6-2:2005, IEC 60950-1 (SELV) and EN 60204-1 (PELV), I | - | - |
|
| Phoenix Contact | - | Communication Between PC and HART Devices | GW HART USB MODEM | - | - | - | - | - | - | - | - | - |
|
| Phoenix Contact | Diode Module | Parallel Connection of Two Power Supply Unit | TRIO2-DIODE/12-24DC/2X20/1X40 | - | - | EMC | - | Screw | - | - | - | - |
|
| Phoenix Contact | Buffer Module | - | QUINT4-BUFFER/24DC/20 | 22.5 → 30V dc | 24V dc | - | 20A | - | - | EAC Certified, IECEE CB Scheme Certified | - | - |
|
| Phoenix Contact | DIN Rail Diode Module | DIN Rail Unit | QUINT-DIODE/48DC/2X20/1X40 | 48V dc | 0.7V | - | 20(Redundacy) A, 40(Inreasing Power) A | - | - | cULus Recognized, UL 508, UL 60950-1, UL listed | - | - |
|
| Phoenix Contact | - | - | QUINT4-BUFFER/24DC/40 | - | 24V dc | - | 40A | - | - | - | - | - |
|
| Phoenix Contact | Redundancy Module | - | - | - | - | - | - | - | Over Voltage Protection | - | - | - |