Solartron Metrology

Unit 6 Station driveTewkesburyGloucestershireGL20 7HHUnited KingdomTel: +(44) 0800 7747755 Web:

Automation & Control Gear

Viewing 1 - 20 of 37 products
Compare selected 0/8
Display:
Price
(Price shown excludes VAT)
Description
Part Details
  • £6.76Each
  • £405.09Each
Solartron Metrology LVDT, ±25mm stroke -40°C +65°C, ±5V
  • Stroke±25mm
  • Energising Voltage Range10 → 30 V dc
  • Output Voltage Range±5V
  • Minimum Operating Temperature0°C
  • Maximum Operating Temperature+65°C
See similar products in LVDT
  • £326.40Each
Solartron Metrology OD5 LVDT Conditioning Module 0°C +60°C, ±10V dc
  • Input Current Range1.1 A, 250 mA
  • Energising Voltage Range90 → 264 V ac
  • Output Voltage Range±10V dc
  • Sensitivity400 → 2500 mV
  • Minimum Operating Temperature0°C
See similar products in LVDT
  • £207.51Each
Solartron Metrology LVDT, ±15mm stroke -40°C +120°C
  • Stroke±15mm
  • Input Current Range1.5 mA
  • Energising Voltage Range1 → 5 Vrms
  • Sensitivity60 mV/V/mm
  • Minimum Operating Temperature-40°C
See similar products in LVDT
  • £117.00Each
Solartron Metrology LVDT, ±3mm stroke -40°C +85°C
  • Stroke±3mm
  • Energising Voltage Range1 → 10 Vrms
  • Sensitivity118 mV/V/mm @ 1kHz, 128 mV/V/mm @ 20kHz, 130 mV/V/mm @ 10kHz, 134 mV/V/mm @ 2kHz, 136 mV/V/mm @ 5kHz
  • Response Time1.5 ms
  • Overall Width42.5mm
See similar products in LVDT
  • £64.03Each
Solartron Metrology LVDT 0°C +70°C, 5 → 10V dc
  • Input Current Range50 mA
  • Energising Voltage Range±7.5 → 18 V dc
  • Output Voltage Range5 → 10V dc
  • Sensitivity2.5 → 3.75 mVrms
  • Overall Height12mm
See similar products in LVDT
  • £385.22Each
Solartron Metrology LVDT, ±15mm stroke 0°C +65°C, ±5V
  • Stroke±15mm
  • Energising Voltage Range10 → 30 V dc
  • Output Voltage Range0 → 5 V, ±10 V, ±5 V
  • Minimum Operating Temperature0°C
  • Maximum Operating Temperature+65°C
See similar products in LVDT
  • £236.21Each
Solartron Metrology LVDT, ±2.5mm stroke -20°C +80°C
  • Stroke±2.5mm
  • Input Current Range10 mA
  • Energising Voltage Range10 → 24 V dc
  • Sensitivity750 mV/mm @ 10 V dc
  • Response Time5 ms
See similar products in LVDT
  • £262.70Each
Solartron Metrology LVDT, ±25mm stroke -40°C +150°C, 5V dc
  • Stroke±25mm
  • Energising Voltage Range1 → 10 Vrms
  • Output Voltage Range5V dc
  • Overall Height83.5mm
  • Overall Depth9.52 (Dia.)mm
See similar products in LVDT
  • £511.04Each
Solartron Metrology LVDT, ±100mm stroke 0°C +65°C, ±5V
  • Stroke±100mm
  • Energising Voltage Range10 → 30 V dc
  • Output Voltage Range0 → 10 V, 0 → 5 V, ±10 V, ±5 V
  • Minimum Operating Temperature0°C
  • Maximum Operating Temperature+65°C
See similar products in LVDT
  • £242.83Each
Solartron Metrology LVDT, ±5mm stroke -20°C +80°C
  • Stroke±5mm
  • Input Current Range13 mA
  • Energising Voltage Range10 → 24 V dc
  • Sensitivity540 mV/mm @ 10 V dc
  • Response Time3 ms
See similar products in LVDT
  • £441.47Each
  • £227.38Each
Solartron Metrology LVDT, ±25mm stroke -40°C +120°C, ±10 V, ±5 V, 0 → 10 V, 0 → 5 V
  • Stroke±25mm
  • Input Current Range0.5 mA
  • Energising Voltage Range10 → 30 V dc
  • Output Voltage Range0 → 10 V, 0 → 5 V, ±10 V, ±5 V
  • Sensitivity21.5 mV/V/mm
See similar products in LVDT
  • £92.72Each
Solartron Metrology LVDT, ±1mm stroke -40°C +85°C
  • Stroke±1mm
  • Input Current Range10 → 13 mA
  • Energising Voltage Range1 → 10 Vrms
  • Sensitivity69 mV/V/mm @ 1kHz, 110 mV/V/mm @ 2kHz, 142 mV/V/mm @ 5kHz, 147 mV/V/mm @ 10kHz, 149 mV/V/mm @ 20kHz
  • Response Time1.5 ms
See similar products in LVDT
  • £11.26Each
Solartron Metrology Return Spring 1.5mm stroke ±1.5 mm output range IP43, IP65
  • Stroke1.5mm
  • Input Current Range1.3 mA
  • Housing MaterialStainless Steel
  • IP RatingIP43, IP65
  • Output Range±1.5 mm
See similar products in Linear Transducers
  • £331.00Each
Solartron Metrology Voltage to Current Signal Conditioner, Voltage 55 → 5000 mV Input, ±10 V dc, ±20 mA Output
  • Input TypeVoltage
  • Output TypeCurrent
  • Signal Conditioner TypeVoltage to Current
  • Input Range55 → 5000 mV
  • Output Range±10 V dc, ±20 mA
See similar products in Signal Conditioning
  • £94.57Each
Solartron Metrology Voltage to Voltage Signal Conditioner, Voltage 0.5 → 750 mV/V Input
  • Input TypeVoltage
  • Output TypeVoltage
  • Signal Conditioner TypeVoltage to Voltage
  • Input Range0.5 → 750 mV/V
  • Output Range5 → 10 V dc
See similar products in Signal Conditioning
  • £249.46Each
Solartron Metrology LVDT, ±50mm stroke -40°C +120°C
  • Stroke±50mm
  • Input Current Range0.6 mA
  • Energising Voltage Range10 → 30 V dc
  • Sensitivity15 mV/V/mm
  • Minimum Operating Temperature-40°C
See similar products in LVDT
  • £172.20Each
Solartron Metrology LVDT, ±6mm stroke -40°C +150°C, 5V dc
  • Stroke±6mm
  • Input Current Range4.5 mA
  • Energising Voltage Range1 → 10 Vrms
  • Output Voltage Range5V dc
  • Sensitivity78 mV/V/mm@ 5 kHz
See similar products in LVDT
  • £149.74Each
Recently Searched
Frequently Asked Questions
Need some help?
Call our Customer Services team on:
03457 201201