PR Electronics 2 Channel Galvanic Barrier, Isolated Driver, Current, Voltage Input, Current, Voltage Output, ATEX
- RS Stock No.:
- 796-6944
- Mfr. Part No.:
- 5105BB
- Brand:
- PR Electronics
2 In stock - FREE next working day delivery available
Added
Price Each
£415.80
(exc. VAT)
£498.96
(inc. VAT)
Units | Per unit |
1 + | £415.80 |
- RS Stock No.:
- 796-6944
- Mfr. Part No.:
- 5105BB
- Brand:
- PR Electronics
Legislation and Compliance
- COO (Country of Origin):
- DK
Product Details
PR Electronics 5105B Ex-isolated Driver
PR Electronics 5105B intrinsically safe isolated driver is a safety barrier for current signals transmitted to I/P converters and displays mounted in hazardous area. The 5105B signal conditioner is based on microprocessor technology for gain and offset. The analogue signal is transmitted at a response time of less than 25 ms. 20 factory-calibrated measurement ranges in the 5105A can be selected by the internal DIP-switches without the need for recalibration. Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighbouring units, up to 84 channels can be mounted per meter.
Features and Benefits
1 : 1 or signal conversion of analogue current / voltage signals
3.75 kV ac galvanic isolation
Loop supply > 17.1 V
Inputs, outputs and supply are floating and galvanically separated
Output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter
Low response time
Universal supply by AC or DC
DIN Rail mounting (vertically or horizontally)
3.75 kV ac galvanic isolation
Loop supply > 17.1 V
Inputs, outputs and supply are floating and galvanically separated
Output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter
Low response time
Universal supply by AC or DC
DIN Rail mounting (vertically or horizontally)
PR Electronics - Ex Interfaces
Specifications
Attribute | Value |
---|---|
Number of Channels | 2 |
Module Type | Isolated Driver |
Barrier Type | Galvanic Barrier |
Output Signal Type | Current, Voltage |
Maximum Voltage | 250V ac |
Hazardous Area Certification | ATEX |
Input Signal Type | Current, Voltage |
Supply Voltage | 19.2 → 300 V dc, 21.6 → 253V ac |
Maximum Operating Temperature | +60°C |
Minimum Operating Temperature | -20°C |
Safety Current Maximum | 400mA |
Safety Voltage Maximum | 250 V ac |
Series | 5100 |
Operating Temperature Range | -20 → +60°C |
- RS Stock No.:
- 796-6944
- Mfr. Part No.:
- 5105BB
- Brand:
- PR Electronics
Related links
- PR Electronics 2 Channel Galvanic Barrier NAMUR Sensor NPN ATEX
- PR Electronics 2 Channel Galvanic Barrier NPN ATEX, IECEx
- PR Electronics 2 Channel Galvanic Barrier ATEX, IECEx
- PR Electronics 1 Channel Galvanic Barrier ATEX, IECEx
- Eaton 1 Channel Zener Barrier Current Input ATEX
- Eaton 2 Channel Zener Barrier Current Input ATEX
- PR Electronics 2 Channel Galvanic Barrier Current Current Output, ATEX
- PR Electronics 2 Channel Galvanic Barrier Relay Output IECEx