PR Electronics 1 Channel Galvanic Barrier, Isolated Driver, ATEX, IECEx
- RS Stock No.:
- 136-8687
- Mfr. Part No.:
- 5105BA
- Brand:
- PR Electronics
Subtotal (1 unit)*
£306.64
(exc. VAT)
£367.97
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 2 unit(s) ready to ship
- Plus 1 unit(s) shipping from 09 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £306.64 |
*price indicative
- RS Stock No.:
- 136-8687
- Mfr. Part No.:
- 5105BA
- Brand:
- PR Electronics
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | PR Electronics | |
Number of Channels | 1 | |
Module Type | Isolated Driver | |
Barrier Type | Galvanic Barrier | |
Maximum Voltage | 253 V ac, 300V dc | |
Hazardous Area Certification | ATEX, IECEx | |
Supply Voltage | 19.2 → 300 V dc, 21.6 → 253V ac | |
Maximum Operating Temperature | +60°C | |
Minimum Operating Temperature | -20°C | |
Safety Current Maximum | 400mA | |
Safety Voltage Maximum | 253 V ac, 300 V dc | |
Series | 5100 | |
Operating Temperature Range | -20 → +60°C | |
Select all | ||
---|---|---|
Brand PR Electronics | ||
Number of Channels 1 | ||
Module Type Isolated Driver | ||
Barrier Type Galvanic Barrier | ||
Maximum Voltage 253 V ac, 300V dc | ||
Hazardous Area Certification ATEX, IECEx | ||
Supply Voltage 19.2 → 300 V dc, 21.6 → 253V ac | ||
Maximum Operating Temperature +60°C | ||
Minimum Operating Temperature -20°C | ||
Safety Current Maximum 400mA | ||
Safety Voltage Maximum 253 V ac, 300 V dc | ||
Series 5100 | ||
Operating Temperature Range -20 → +60°C | ||
- COO (Country of Origin):
- DK
PR Electronics 5105B Ex-isolated Driver
PR Electronics 5105B intrinsically safe isolated driver is a safety barrier for current signals transmitted to I/P converters and displays mounted in hazardous area. The 5105B signal conditioner is based on microprocessor technology for gain and offset. The analogue signal is transmitted at a response time of less than 25 ms. 20 factory-calibrated measurement ranges in the 5105A can be selected by the internal DIP-switches without the need for recalibration. Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighbouring units, up to 84 channels can be mounted per meter.
Features and Benefits
1 : 1 or signal conversion of analogue current / voltage signals
3.75 kV ac galvanic isolation
Loop supply > 17.1 V
Inputs, outputs and supply are floating and galvanically separated
Output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter
Low response time
Universal supply by AC or DC
DIN Rail mounting (vertically or horizontally)
3.75 kV ac galvanic isolation
Loop supply > 17.1 V
Inputs, outputs and supply are floating and galvanically separated
Output can be connected either as an active current / voltage transmitter or as a 2-wire transmitter
Low response time
Universal supply by AC or DC
DIN Rail mounting (vertically or horizontally)
PR Electronics - Ex Interfaces
Related links
- PR Electronics 1 Channel Galvanic Barrier NPN ATEX, IECEx
- PR Electronics 1 Channel Galvanic Barrier ATEX, IECEx
- PR Electronics 2 Channel Galvanic Barrier Current Current ATEX
- PR Electronics 1 Channel Galvanic Barrier Current Current Output, ATEX
- PR Electronics 2 Channel Galvanic Barrier NPN ATEX, IECEx
- PR Electronics 2 Channel Galvanic Barrier Relay Output IECEx
- PR Electronics 2 Channel Galvanic Barrier ATEX, IECEx
- Eaton 2 Channel Zener Barrier Current Input ATEX