Phoenix Contact 1 Channel Galvanic Barrier, Power & Error Message Module, Voltage Input, Relay Output, ATEX
- RS Stock No.:
- 709-9640
- Mfr. Part No.:
- 2865625
- Brand:
- Phoenix Contact
Subtotal (1 unit)*
£100.60
(exc. VAT)
£120.72
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 1 unit(s) ready to ship
- Plus 999,999,998 unit(s) shipping from 14 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £100.60 |
*price indicative
- RS Stock No.:
- 709-9640
- Mfr. Part No.:
- 2865625
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Phoenix Contact | |
Number of Channels | 1 | |
Module Type | Power & Error Message Module | |
Barrier Type | Galvanic Barrier | |
Output Signal Type | Relay | |
Hazardous Area Certification | ATEX | |
Input Signal Type | Voltage | |
Minimum Operating Temperature | -20°C | |
Supply Voltage | 19.2 → 30V dc | |
Maximum Operating Temperature | +60°C | |
Safety Current Maximum | 3.75A | |
Safety Voltage Maximum | 30 V dc | |
Series | MACX MCR-PTB | |
Operating Temperature Range | -20 → +60°C | |
Select all | ||
---|---|---|
Brand Phoenix Contact | ||
Number of Channels 1 | ||
Module Type Power & Error Message Module | ||
Barrier Type Galvanic Barrier | ||
Output Signal Type Relay | ||
Hazardous Area Certification ATEX | ||
Input Signal Type Voltage | ||
Minimum Operating Temperature -20°C | ||
Supply Voltage 19.2 → 30V dc | ||
Maximum Operating Temperature +60°C | ||
Safety Current Maximum 3.75A | ||
Safety Voltage Maximum 30 V dc | ||
Series MACX MCR-PTB | ||
Operating Temperature Range -20 → +60°C | ||
- COO (Country of Origin):
- DE
Phoenix Contact MACX MCR-PTB Series Galvanic Barrier, 1 Channel, Relay Output Signal Type - 2865625
This galvanic barrier is designed as a single-channel power and error message module, providing essential voltage isolation solutions. With an operational capacity of up to 50V AC/DC, this device effectively protects sensitive electronics in hazardous environments. The unit operates within a wide temperature range of -40°C to +60°C, making it suitable for diverse applications in challenging conditions.
Features & Benefits
• ATEX certified barrier ensures compliance in hazardous areas
• Relay output signal provides reliable communication with connected systems
• Supports supply voltage from 19.2 to 30V DC for flexibility
• Capable of handling currents up to 3.75A for robust performance
• Designed for effective voltage isolation to safeguard connected devices
• Compact and efficient design maximises space in control cabinets
• Relay output signal provides reliable communication with connected systems
• Supports supply voltage from 19.2 to 30V DC for flexibility
• Capable of handling currents up to 3.75A for robust performance
• Designed for effective voltage isolation to safeguard connected devices
• Compact and efficient design maximises space in control cabinets
Applications
• Used for industrial automation systems requiring enhanced safety
• Utilised in electrical and mechanical control circuits
• Ideal for voltage signal isolation in sensitive electronic equipment
• Field in potentially explosive atmospheres
• Utilised in electrical and mechanical control circuits
• Ideal for voltage signal isolation in sensitive electronic equipment
• Field in potentially explosive atmospheres
What is the significance of the ATEX certification?
The ATEX certification indicates that this product is designed for safe use in potentially explosive atmospheres, ensuring effective operation under stringent safety regulations.
How does the relay output signal enhance functionality?
The relay output signal facilitates reliable communication with other system components, enabling quick response to errors or changes in status, which is crucial for maintaining operational integrity.
What operational conditions can this device withstand?
This device can function within temperatures ranging from -40°C to +60°C, making it suitable for extreme environments commonly found in industrial applications.
Can this device handle multiple devices at once?
While designed for single-channel use, it effectively isolates voltage for various connected devices within its specifications, ensuring protection without compromising system performance.
Related links
- Endress+Hauser Converter Module Relay Output, Zone 2
- Phoenix Contact 1 Channel Galvanic Barrier NAMUR Sensor Relay Output, ATEX
- Turck 1 Channel Galvanic Barrier NAMUR Sensor Relay Output IECEx
- Phoenix Contact 2 Channel Galvanic Barrier NAMUR Sensor Relay Output, ATEX
- Turck 2 Channel Galvanic Barrier NAMUR Sensor Relay Output IECEx
- Phoenix Contact 1 Channel Galvanic Barrier Current Current ATEX
- PR Electronics 1 Channel Galvanic Barrier Current Current Output, ATEX
- Turck 1 Channel Galvanic Barrier Current Current Output IECEx