Turck 2 Channel Galvanic Barrier, Isolating Amplifier, NAMUR Sensor, Switch Input, Relay Output, ATEX, IECEx
- RS Stock No.:
- 808-6510
- Mfr. Part No.:
- IM1-22EX-R
- Brand:
- Turck
Subtotal (1 unit)*
£178.30
(exc. VAT)
£213.96
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 79 unit(s) ready to ship
- Plus 11 unit(s) ready to ship from another location
- Plus 12 unit(s) shipping from 15 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £178.30 |
*price indicative
- RS Stock No.:
- 808-6510
- Mfr. Part No.:
- IM1-22EX-R
- Brand:
- Turck
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Turck | |
Number of Channels | 2 | |
Module Type | Isolating Amplifier | |
Barrier Type | Galvanic Barrier | |
Output Signal Type | Relay | |
Maximum Voltage | 250V | |
Hazardous Area Certification | ATEX, IECEx | |
Input Signal Type | NAMUR Sensor, Switch | |
Supply Voltage | 20 → 125 V dc, 20 → 250V ac | |
Minimum Operating Temperature | -25°C | |
Maximum Operating Temperature | +70°C | |
Safety Voltage Maximum | 250 V | |
Series | IM | |
Operating Temperature Range | -25 → +70°C | |
Select all | ||
---|---|---|
Brand Turck | ||
Number of Channels 2 | ||
Module Type Isolating Amplifier | ||
Barrier Type Galvanic Barrier | ||
Output Signal Type Relay | ||
Maximum Voltage 250V | ||
Hazardous Area Certification ATEX, IECEx | ||
Input Signal Type NAMUR Sensor, Switch | ||
Supply Voltage 20 → 125 V dc, 20 → 250V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +70°C | ||
Safety Voltage Maximum 250 V | ||
Series IM | ||
Operating Temperature Range -25 → +70°C | ||
- COO (Country of Origin):
- DE
IM1 Isolating Switching Amplifier
Professional range of galvanically isolated switching amplifiers for the transmission of binary switching signals. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications
Features of the IM1 Isolating Switching Amplifier Range
Intrinsically safe input circuits in accordance to ATEX II (1) GD, II 3 G
NAMUR sensor & mechanical switch connections
Supports a N/O relay output per channel
Input circuit monitoring function for detection of short circuit and/or wire-break for each channel, this feature can be switched on/off
Detachable terminal blocks
LED indication of operational readiness
Intrinsically safe input circuits in accordance to ATEX II (1) GD, II 3 G
NAMUR sensor & mechanical switch connections
Supports a N/O relay output per channel
Input circuit monitoring function for detection of short circuit and/or wire-break for each channel, this feature can be switched on/off
Detachable terminal blocks
LED indication of operational readiness
Note
When using mechanical contacts, wire-break & short circuit monitoring must be switched off or wired with resistors
Standards
ATEX 2553, ATEX 552968C, UL, KOSHA, IECEx, NEPSI, FM

Turck Galvanic Barrier, Isolating Switching Amplifier Type, 2 x Relay Outputs - IM1 Series - IM1-22EX-R
For the safe transmission of your control signals, make the switch to this Turck galvanic barrier. It's an isolating switching amplifier that prevents electrical conduction between an 8.2V DC NAMUR sensor and a 250V AC output without affecting the signal. It has two relay outputs, so you can make or break multiple circuits as needed. Sudden voltage surges are no problem, as this product has been isolation-tested up to 2.5kV. Optional wire-break and short-circuit monitoring give additional peace of mind.
Features & Benefits
• Broad -25°C to +70°C operating temperature range is well-suited to harsh working areas
• Maximum power consumption of 3W shows it's an energy-saving component
• Built-in LED indicators to monitor the status and operation of your setup
• Operating voltage ranges of 20 to 250V AC and 20 to 125V DC for use with universal supply sources
• Maximum power consumption of 3W shows it's an energy-saving component
• Built-in LED indicators to monitor the status and operation of your setup
• Operating voltage ranges of 20 to 250V AC and 20 to 125V DC for use with universal supply sources
Applications
• Medical equipment
• Power supply design
• Automotive industry
• Renewable energy installations
• Power supply design
• Automotive industry
• Renewable energy installations
Can I use this unit to control DC circuits?
Yes, you can. For flexibility, this product lets you activate or de-activate a connected DC circuit with a rating of up to 30V.
Turck Banner DIN Rail Mounting
Related links
- Turck 2 Channel Galvanic Barrier NAMUR Sensor Relay Output IECEx
- Turck 1 Channel Galvanic Barrier NAMUR Sensor Relay Output IECEx
- Turck 2 Channel Galvanic Barrier Current Input ATEX, IECEx
- Phoenix Contact 1 Channel Galvanic Barrier NAMUR Sensor Relay Output, ATEX
- Phoenix Contact 2 Channel Galvanic Barrier NAMUR Sensor Relay Output, ATEX
- Phoenix Contact 1 Channel Galvanic Barrier NAMUR Sensor Transistor Output, ATEX
- Turck 2 Channel Galvanic Barrier Current ATEX, IECEx
- Turck 2 Channel Galvanic Barrier Current Voltage Output IECEx