United Automation FC36M, Thyristor Trigger Module
- RS Stock No.:
- 232-9347
- Mfr. Part No.:
- FC36M
- Brand:
- United Automation
Bulk discount available
Subtotal (1 unit)*
£319.18
(exc. VAT)
£383.02
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 9 unit(s) ready to ship
- Plus 5 unit(s) shipping from 30 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 - 1 | £319.18 |
2 - 4 | £310.56 |
5 - 9 | £302.26 |
10 - 19 | £294.60 |
20 + | £287.27 |
*price indicative
- RS Stock No.:
- 232-9347
- Mfr. Part No.:
- FC36M
- Brand:
- United Automation
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | United Automation | |
Output Isolation | 3500Vrms | |
Input Voltage DC | 5V dc | |
Dimensions | 162 x 108 x 40mm | |
Minimum Operating Temperature | 0 °C | |
Maximum Operating Temperature | +65 °C | |
Select all | ||
---|---|---|
Brand United Automation | ||
Output Isolation 3500Vrms | ||
Input Voltage DC 5V dc | ||
Dimensions 162 x 108 x 40mm | ||
Minimum Operating Temperature 0 °C | ||
Maximum Operating Temperature +65 °C | ||
- COO (Country of Origin):
- GB
Phase Angle & Burst Firing Three-Phase, FC36M - A34411 (No DIN housing), 415V
A microprocessor based thyristor firing control PCB with both Phase Angle and Burst Firing options.
Suitable for ac/dc resistive/inductive loads, via thyristor pairs on 3-phase stacks
No external phasing transformers required
Analogue control inputs 0-5Vdc and 4-20mA current loop
Digital isolated control, opto-coupled +5 → +25Vdc
Selectable current limit with LED indication
Over-current latching trip to 150% LED indication
Selectable resistive/inductive loads
Selectable phase reversal
Output status indication
No external phasing transformers required
Analogue control inputs 0-5Vdc and 4-20mA current loop
Digital isolated control, opto-coupled +5 → +25Vdc
Selectable current limit with LED indication
Over-current latching trip to 150% LED indication
Selectable resistive/inductive loads
Selectable phase reversal
Output status indication
The number of complete mains cycles during fixed repeating periods (typically 1 to 10 seconds) is varied, thus altering the duty cycle or on-/off-time ratio. Trigger pulses coincide with the zero-crossing times of the mains supply thus ensuring no RFI is produced when using resistive loads.
Related links
- United Automation DMFC12 230VAC, Thyristor Trigger Module
- United Automation A34462, Thyristor Trigger Module
- United Automation DMFC36, Thyristor Trigger Module
- United Automation STOM-1, Thyristor Trigger Module
- United Automation AFM11, Thyristor Trigger Module
- United Automation FC11AL, Thyristor Trigger Module
- United Automation AVR-25, Thyristor Trigger Module
- United Automation PAC-2, Thyristor Trigger Module