Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 1A Current Rating
- RS Stock No.:
- 899-1878
- Mfr. Part No.:
- 2G1UM
- Brand:
- Altech
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS Stock No.:
- 899-1878
- Mfr. Part No.:
- 2G1UM
- Brand:
- Altech
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Altech | |
Current Rating | 1A | |
Number of Poles | 2 | |
Voltage Rating | 277V | |
Width | 35mm | |
Series | V-EA | |
Tripping Mechanism | Thermal-Magnetic | |
Reset Actuator Type | Handle | |
Tripping Characteristics | Type G | |
Rated AC Voltage | 480Y/277V | |
Mounting Style | DIN Rail Mount | |
Overall Length | 93.3mm | |
Break Time | Time Delay | |
Rated DC Voltage | 80V | |
Terminal Contact Type | Ring Tongue Terminal | |
Overall Dimensions | 93.3 x 35 x 74.7mm | |
Circuit Breaker Type | Thermal Magnetic Circuit Breaker | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Special Features | IP20 Terminal Protection | |
Overall Depth | 74.7mm | |
Select all | ||
---|---|---|
Brand Altech | ||
Current Rating 1A | ||
Number of Poles 2 | ||
Voltage Rating 277V | ||
Width 35mm | ||
Series V-EA | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Handle | ||
Tripping Characteristics Type G | ||
Rated AC Voltage 480Y/277V | ||
Mounting Style DIN Rail Mount | ||
Overall Length 93.3mm | ||
Break Time Time Delay | ||
Rated DC Voltage 80V | ||
Terminal Contact Type Ring Tongue Terminal | ||
Overall Dimensions 93.3 x 35 x 74.7mm | ||
Circuit Breaker Type Thermal Magnetic Circuit Breaker | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Special Features IP20 Terminal Protection | ||
Overall Depth 74.7mm | ||
- COO (Country of Origin):
- US
Altech V-EA Series DIN Rail
Thermal Magnetic Circuit Breakers are found in most distribution boards. The thermal portion provides an "inverse time" response feature, which trips the circuit breaker sooner for larger overcurrents. The Altech V-EA series are primarily DIN Rail mounted and provide a compact solution to your protection requirements. All models are highly reliable and excellent quality.
DIN Rail Mounted
17.5mm width per pole
Thermal Magnetic
10kA Short Circuit Withstand Capacity
17.5mm width per pole
Thermal Magnetic
10kA Short Circuit Withstand Capacity
Thermal Magnetic Convertible
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).
Related links
- Altech Thermal Circuit Breaker - V-EA 2 Pole 480Y/277V Voltage Rating DIN Rail Mount, 1A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 15A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 13A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 40A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 30A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 6A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 0.3A Current Rating
- Altech Thermal Circuit Breaker - V-EA 2 Pole 277V Voltage Rating DIN Rail Mount, 25A Current Rating