Schneider Electric TeSys GV3 Thermal Circuit Breaker - 3-Pole, Direct, 23A Current Rating, 100 kA, 690V ac

Subtotal (1 unit)*

£176.59

(exc. VAT)

£211.91

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • Plus 3 unit(s) shipping from 06 April 2026
  • Plus 2 unit(s) shipping from 06 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£176.59

*price indicative

RS Stock No.:
272-909
Mfr. Part No.:
GV3P25
Brand:
Schneider Electric
Find similar products by selecting one or more attributes.
Select all

Brand

Schneider Electric

Current Rating

23A

Product Type

Thermal Circuit Breaker

Series

GV3

Number of Poles

3

Range

TeSys

Width

55mm

Mount Type

Direct

Terminal Type

Screw

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

Height

160mm

Rated AC Voltage

690V ac

Standards/Approvals

CE, RoHS

Depth

136mm

Break Time

Medium

Breaking Capacity

100kA

COO (Country of Origin):
FR

Schneider Electric GV3 Series Thermal Circuit Breaker, 25A Current, 100kA Breaking Capacity - GV3P25


This thermal circuit-breaker is a three-pole device designed to protect motors and associated circuits in industrial AC networks. It combines thermal-magnetic tripping to guard against overloads and short circuits, and is intended for direct mounting in control panels or on DIN rails in automation, electrical and mechanical installations.

Features & Benefits


• 25A setting range provides precise motor overload protection
• 100 kA breaking capacity enables high fault-interruption capability
• Thermal-magnetic tripping gives combined overload and short-circuit response
• Toggle reset actuator allows quick manual reclosure after trip
• Screw-terminal design ensures secure conductor connection
• Rated for 690V AC operation across common industrial frequencies

Applications


• Suitable for motor protection in panel-mounted starter units
• Used with three-phase drives in factory automation systems
• Ideal for electrical distribution in machinery control cabinets
• Can be used for protection of pumps and compressors on site

What adjustment range is available for thermal protection?


The thermal element is adjustable to protect motors from 17A up to 25 A, allowing matching to motor full-load current.

How does the device behave under phase loss?


It includes phase-failure sensitivity so it will react to single-phase conditions to protect three-phase motors.

What are its endurance characteristics in industrial duty?


Mechanical and electrical durability are specified at 50,000 cycles, suitable for continuous rated duty in AC-3 applications.

How is the unit mounted and fixed within an enclosure?


It can be clipped on a 35mm symmetrical DIN rail or secured to a panel using three M4 screws for rigid installation.

What environmental limits apply during operation?


The breaker is designed for ambient temperatures from -20 to 60 °C and an operating altitude up to 3,000 m.

Standards

IEC 947 and UL 508 type E certification