PR Electronics 6400 Temperature Transmitter Thermocouple, Potentiometer, RTD Input 30V dc, 85 °C, -50 °C
- RS Stock No.:
- 270-1740
- Mfr. Part No.:
- 6437D1--
- Brand:
- PR Electronics
Subtotal (1 unit)*
£413.30
(exc. VAT)
£495.96
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | £413.30 |
*price indicative
- RS Stock No.:
- 270-1740
- Mfr. Part No.:
- 6437D1--
- Brand:
- PR Electronics
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | PR Electronics | |
| Product Type | Temperature Transmitter | |
| Input Type | Thermocouple, Potentiometer, RTD | |
| Output Type | Current | |
| Diameter | 104mm | |
| Minimum Temperature Input | -40°C | |
| Maximum Temperature Input | 85°C | |
| Series | 6400 | |
| Maximum Supply Voltage | 30V dc | |
| Minimum Operating Temperature | -50°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | RoHS, EAC | |
| Hazardous Area Certification | ATEX | |
| Select all | ||
|---|---|---|
Brand PR Electronics | ||
Product Type Temperature Transmitter | ||
Input Type Thermocouple, Potentiometer, RTD | ||
Output Type Current | ||
Diameter 104mm | ||
Minimum Temperature Input -40°C | ||
Maximum Temperature Input 85°C | ||
Series 6400 | ||
Maximum Supply Voltage 30V dc | ||
Minimum Operating Temperature -50°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals RoHS, EAC | ||
Hazardous Area Certification ATEX | ||
- COO (Country of Origin):
- DK
The PR Electronics 2-wire HART 7 temperature transmitter is for measurement and conversion of wide span linear resistance and potentiometer. Its single or true dual inputs accepts the widest range of dual input combinations, The sensor redundancy output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime and drift detection alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
Extensive sensor matching
superior accuracy
Related links
- PR Electronics Thermocouple Potentiometer Input
- PR Electronics RTD Potentiometer Input
- PR Electronics Thermocouple Voltage Input
- PR Electronics Thermocouple Input
- PR Electronics RTD Thermocouple Input
- Phoenix Contact MACX MCR Series Signal Conditioner Thermocouple RTD Input 230
- PR Electronics 6300 Temperature Transmitter Voltage RTD Input -40 °C
- PR Electronics RTD, Thermocouple Input