Better World
Schneider Electric Surge Protector, 20kA, DIN Rail Mount
- RS Stock No.:
- 776-3890
- Mfr. Part No.:
- A9L16294
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£961.09
(exc. VAT)
£1,153.31
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 4 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £961.09 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 776-3890
- Mfr. Part No.:
- A9L16294
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Schneider Electric | |
Device Type | Surge Arrestor | |
Maximum Surge Current | 20kA | |
Range | Acti 9 | |
Series | iPRD | |
Mounting Style | DIN Rail | |
Length | 94mm | |
Width | 131.5mm | |
Depth | 75.9mm | |
Dimensions | 94 x 131.5 x 75.9mm | |
Minimum Operating Temperature | -25°C | |
Maximum Operating Temperature | +60°C | |
Operating Temperature Range | -25 → +60 °C | |
Better World Product | Yes | |
Better World Verification | Green Premium | |
Select all | ||
---|---|---|
Brand Schneider Electric | ||
Device Type Surge Arrestor | ||
Maximum Surge Current 20kA | ||
Range Acti 9 | ||
Series iPRD | ||
Mounting Style DIN Rail | ||
Length 94mm | ||
Width 131.5mm | ||
Depth 75.9mm | ||
Dimensions 94 x 131.5 x 75.9mm | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +60°C | ||
Operating Temperature Range -25 → +60 °C | ||
Better World Product Yes | ||
Better World Verification Green Premium | ||
- COO (Country of Origin):
- DE
Schneider Electric iQuick PRD40r Series Surge Arrester, 20kA Maximum Surge Current, DIN Rail Mounting Style - A9L16294
This surge arrester provides effective surge protection for electrical distribution systems. Its compact DIN rail design allows for straightforward installation and integration into existing setups, making it essential for reliable protection against voltage spikes and transients. With a maximum surge current capacity of 20kA, it enhances the durability and safety of electronic installations.
Features & Benefits
• Impulse discharge current capacity of 20kA
• Integrated remote signalling for immediate alerts
• Utilises advanced MOV and GDT technologies for effectiveness
• Compatible with various earthing systems, including TN-S and TT
• Rated operational voltage of 230/400V AC (+/- 10%)
• Compliant with EN 61643-112012 and IEC 61643-112011 standards
• Integrated remote signalling for immediate alerts
• Utilises advanced MOV and GDT technologies for effectiveness
• Compatible with various earthing systems, including TN-S and TT
• Rated operational voltage of 230/400V AC (+/- 10%)
• Compliant with EN 61643-112012 and IEC 61643-112011 standards
Applications
• Protects industrial electrical distribution networks
• Suitable for automation systems requiring surge protection
• Ideal for environments susceptible to high surge risk and voltage fluctuations
• Appropriate for installations on DIN rails in commercial settings
• Suitable for automation systems requiring surge protection
• Ideal for environments susceptible to high surge risk and voltage fluctuations
• Appropriate for installations on DIN rails in commercial settings
What should be considered before installation?
Ensure compatibility with existing electrical systems and adhere to local regulations during installation.
How does remote signalling enhance functionality?
It provides real-time notifications of surge events, enabling swift action to prevent damage.
Can it be used in outdoor environments?
It is suitable for indoor use
outdoor applications necessitate additional protective measures.
What is the maintenance requirement for this device?
Regular inspections are recommended to verify functionality and assess wear over time.
Is it compatible with different electrical configurations?
Yes, it supports various earthing systems and operational voltages for versatility.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Related links
- Schneider Electric Surge Protector DIN Rail Mount
- Phoenix Contact Surge Protector DIN Rail Mount
- Phoenix Contact Surge Protector 30V dc, DIN Rail Mount
- Phoenix Contact Surge Protector 180V (Volts), DIN Rail Mount
- Phoenix Contact Surge Protector 55.2V dc, DIN Rail Mount
- Phoenix Contact Surge Protector 53V dc, DIN Rail Mount
- RS PRO Industrial Surge Protector 250 V, DIN Rail Mount
- Schneider Electric Surge Protector Plug In Mount