Phoenix Contact Single Phase Surge Arrester, 40kA, = 2.6kV, DIN Rail Mount
- RS Stock No.:
- 249-9511
- Mfr. Part No.:
- 2801164
- Brand:
- Phoenix Contact
Unavailable
RS will no longer stock this product.
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£241.16
(exc. VAT)
£289.39
(inc. VAT)
- RS Stock No.:
- 249-9511
- Mfr. Part No.:
- 2801164
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Phoenix Contact | |
Device Type | Surge Arrestor | |
Maximum Surge Current | 40kA | |
Voltage Protection Rating | = 2.6kV | |
Range | VALVETRAB PV | |
Series | VAL-MS | |
Electrical Phase | Single | |
Mounting Style | DIN Rail | |
Select all | ||
---|---|---|
Brand Phoenix Contact | ||
Device Type Surge Arrestor | ||
Maximum Surge Current 40kA | ||
Voltage Protection Rating = 2.6kV | ||
Range VALVETRAB PV | ||
Series VAL-MS | ||
Electrical Phase Single | ||
Mounting Style DIN Rail | ||
- COO (Country of Origin):
- DE
The phoenix contact Lightning/surge arrester type 1/2 - VAL-MS-T1/T2
600DC-PV/2+V-FM is a device for 2-pos. isolated and grounded 600 V DC PV voltage systems, for DIN rail mounting, 3-pos. base element with remote indication contact, three pluggable temperature-monitored protective elements, status message at each plug. It has been quality proven millions of times over in the widest range of applications. Rapid installation with bridges, thanks to industry-standard overall width of 1 HP. Easy testing and insulation measurement.
600DC-PV/2+V-FM is a device for 2-pos. isolated and grounded 600 V DC PV voltage systems, for DIN rail mounting, 3-pos. base element with remote indication contact, three pluggable temperature-monitored protective elements, status message at each plug. It has been quality proven millions of times over in the widest range of applications. Rapid installation with bridges, thanks to industry-standard overall width of 1 HP. Easy testing and insulation measurement.
IEC test classification - PV I / II PV T1 / T2
EN type - T1 / T2
Distance between live and grounded parts - 8 mm
Installation location - Interior
Installation location of the disconnect device -Internal
Accessibility - Accessible
Connection configuration - Y configuration
SPD failure behaviour - OCFM
Surge protection fault message - Optical, remote indicator contact
Overvoltage category - III
Pollution degree - 2
Connection name - Remote fault indicator contact
Switching function - Changeover contact Connection method - Screw connection
Screw thread - M5
Tightening torque - 3 Nm (1.5mm² to 16mm²) 4.5 Nm (25mm² to 35mm²)
Stripping length - 16 mm
Conductor cross section flexible - 1.5mm²to 25 mm²
EN type - T1 / T2
Distance between live and grounded parts - 8 mm
Installation location - Interior
Installation location of the disconnect device -Internal
Accessibility - Accessible
Connection configuration - Y configuration
SPD failure behaviour - OCFM
Surge protection fault message - Optical, remote indicator contact
Overvoltage category - III
Pollution degree - 2
Connection name - Remote fault indicator contact
Switching function - Changeover contact Connection method - Screw connection
Screw thread - M5
Tightening torque - 3 Nm (1.5mm² to 16mm²) 4.5 Nm (25mm² to 35mm²)
Stripping length - 16 mm
Conductor cross section flexible - 1.5mm²to 25 mm²
Related links
- Phoenix Contact Three Phase Surge Arrester = 2.6kV, DIN Rail Mount
- Eaton Surge Protector 2.6kV, DIN Rail Mount
- Phoenix Contact Single Phase Surge Arrester = 1.4kV, DIN Rail Mount
- Phoenix Contact Single Phase Surge Arrester 260V ac, DIN Rail Mount
- Phoenix Contact Single Phase Surge Arrester = 1.5kV, DIN Rail Mount
- Legrand Single Phase Surge Arrester 1.7kV, DIN Rail Mount
- Legrand Single Phase Surge Arrester 2.5kV, DIN Rail Mount
- Phoenix Contact Three Phase Surge Arrester = 1.5kV, DIN Rail Mount