Castle Datalogging Sound Level Meter, 35dB to 140dB, 20kHz max with RS Calibration
- RS Stock No.:
- 921-3075
- Mfr. Part No.:
- 01GA216B
- Brand:
- Castle
Subtotal (1 unit)*
£650.00
(exc. VAT)
£780.00
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 3 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £650.00 |
*price indicative
- RS Stock No.:
- 921-3075
- Mfr. Part No.:
- 01GA216B
- Brand:
- Castle
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Castle | |
Maximum Sound Level | 140dB | |
Minimum Sound Level | 35dB | |
Resolution | 0.1 dB | |
DOSE Measurement | Yes | |
Weighting | A, C | |
Display Type | LCD | |
Battery Type | Alkaline, PP3 | |
Calibrated | RSCAL | |
Fast/Slow Time Averaging | Both | |
Data Logging | Yes | |
Maximum Frequency | 20kHz | |
Minimum Frequency | 1 Hz | |
Select all | ||
---|---|---|
Brand Castle | ||
Maximum Sound Level 140dB | ||
Minimum Sound Level 35dB | ||
Resolution 0.1 dB | ||
DOSE Measurement Yes | ||
Weighting A, C | ||
Display Type LCD | ||
Battery Type Alkaline, PP3 | ||
Calibrated RSCAL | ||
Fast/Slow Time Averaging Both | ||
Data Logging Yes | ||
Maximum Frequency 20kHz | ||
Minimum Frequency 1 Hz | ||
- COO (Country of Origin):
- GB
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Sound Pressure (Lp) to 0.1 dB resolution
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Castle Sonus B, Class 2 Sound Level Meter with RS Calibration
The Castle SONUS B GA216B sound level meter is designed for general survey work and engineering applications by fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Class 2 sound meter fully compliant with IEC 61672-1:2002.
Sound Pressure (Lp) to 0.1 dB resolution
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Over Load and Under Range indication
For fire alarm installation testing, the regulations states that a Class 2 sound meter should be used that is capable of measuring the maximum sound pressure level. The SONUS B is perfect for this application as it meets all of these requirements.
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Housed in tough, crack-resistant ABS plastic
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
Dimensions 60mm x 30mm (excluding pocket clip) x 135mm (210mm with microphone)
Weight 200g (without battery)
Related links
- Castle Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonus GA216L Class 2 Datalogging Sound Level Meter 20kHz max
- Castle Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonus GA216L Class 2 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonik GA142S Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle Sonus GA216B Class 2 Sound Level Meter 8kHz max
- Castle Sonik GA142SE Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration
- Castle dBAir GA141S Class 1 Datalogging Sound Level Meter 20kHz max with RS Calibration