Phoenix Contact MINI MCR Series Signal Conditioner, RTD Input, Current, Voltage Output, 9.6 → 30V dc Supply
- RS Stock No.:
- 849-6392
- Mfr. Part No.:
- 2902052
- Brand:
- Phoenix Contact
Subtotal (1 unit)*
£197.56
(exc. VAT)
£237.07
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 3 unit(s) ready to ship
- Plus 19 unit(s) ready to ship from another location
- Plus 3 unit(s) shipping from 05 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £197.56 |
*price indicative
- RS Stock No.:
- 849-6392
- Mfr. Part No.:
- 2902052
- Brand:
- Phoenix Contact
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Phoenix Contact | |
Module Type | Temperature Converter | |
Input Signal Type | RTD | |
Output Signal Type | Current, Voltage | |
Input Range | 0 → 4000 Ω, -200 → +850°C | |
Output Range | 0 → 10.5 V, 0 → 24.6mA | |
Supply Voltage | 9.6 → 30V dc | |
Mounting Type | DIN Rail Mount | |
Operating Temperature Range | -40 → +70°C | |
Series | MINI MCR | |
Maximum Operating Temperature | +70°C | |
Minimum Operating Temperature | -40°C | |
Termination | Plug-In | |
Select all | ||
---|---|---|
Brand Phoenix Contact | ||
Module Type Temperature Converter | ||
Input Signal Type RTD | ||
Output Signal Type Current, Voltage | ||
Input Range 0 → 4000 Ω, -200 → +850°C | ||
Output Range 0 → 10.5 V, 0 → 24.6mA | ||
Supply Voltage 9.6 → 30V dc | ||
Mounting Type DIN Rail Mount | ||
Operating Temperature Range -40 → +70°C | ||
Series MINI MCR | ||
Maximum Operating Temperature +70°C | ||
Minimum Operating Temperature -40°C | ||
Termination Plug-In | ||
- COO (Country of Origin):
- DE
MINI Analog Pro Signal Conditioners
The Mini Analog Pro signal conditioners from Phoenix Contact are the first 6mm range with plug-in connection technology. Using the latest switching technology, applications are made quicker and easier with the signal conditioners' highly compact and visible housing, easily accessible terminal points and current measurement. Users also benefit from simple configuration via DIP switches as well as extended configuration via software or smartphone app without needing additional accessories plus supports NFC communication
Easy startup and servicing: measures signals without disconnecting current loops and optional disconnect function
Excellent signal quality
Available with extended supply voltages and operating temperatures to suit a wide range of applications
Wiring with screw connection or tool-free plug-in technology
Excellent signal quality
Available with extended supply voltages and operating temperatures to suit a wide range of applications
Wiring with screw connection or tool-free plug-in technology
Phoenix Contact Resistance Measuring Transducer - MINIMCR-2-RTD-UIPT - 2902052
This transducer from Phoenix Contact converts resistance into a linear and freely configurable current or voltage signal. It's suitable for connecting to resistance thermometers and remote resistance-type sensors with 2, 3 and 4 conductor connectors.
The component's plug-in technology means it can be installed without the need for specialist equipment. Its terminal points are user-friendly and easy to access, which makes wiring conductors to the unit simple. This versatile transducer also supports fault-reporting technology and near-field communication (NFC), which allows it to wirelessly communicate with other NFC devices within short range.
You can manually configure the transducer using dual in-line packaging (DIP) switches or choose the mobile route and use the smartphone app. It meets Ex Zone standards for the classification of hazardous areas and has a flameproof enclosure to prevent potential electric ignitions.
The component's plug-in technology means it can be installed without the need for specialist equipment. Its terminal points are user-friendly and easy to access, which makes wiring conductors to the unit simple. This versatile transducer also supports fault-reporting technology and near-field communication (NFC), which allows it to wirelessly communicate with other NFC devices within short range.
You can manually configure the transducer using dual in-line packaging (DIP) switches or choose the mobile route and use the smartphone app. It meets Ex Zone standards for the classification of hazardous areas and has a flameproof enclosure to prevent potential electric ignitions.
• Input range of 0 Ω to 4000 Ω and -200°C to +850°C
• Operating temperature range of -40°C to +70°C
• DIN rail mounting type
• Output range of 0 V to 10.5 V and 0 mA to 24.6 mA
• RTD (resistance temperature detector) to current and RTD to voltage signal conditioner type
• Supply voltage of 9.6 V DC to 30 V DC
• Operating temperature range of -40°C to +70°C
• DIN rail mounting type
• Output range of 0 V to 10.5 V and 0 mA to 24.6 mA
• RTD (resistance temperature detector) to current and RTD to voltage signal conditioner type
• Supply voltage of 9.6 V DC to 30 V DC
Related links
- Phoenix Contact MINI MCR Series Signal Conditioner Current 9.6 → 30V dc Supply,
- Phoenix Contact MINI MCR Series Signal Conditioner Current 9.6 → 30V dc Supply,
- Phoenix Contact MINI MCR Series Signal Conditioner Voltage Output, 9.6 → 30V dc Supply
- Phoenix Contact MINI MCR Series Signal Conditioner Voltage Output, 9.6 → 30V dc Supply
- Phoenix Contact MINI MCR Series Signal Conditioner Voltage Output ATEX
- Phoenix Contact MINI MCR Series Signal Conditioner Current 9.6 → 30V dc
- Phoenix Contact MINI MCR Series Signal Conditioner Current 9.6 → 30V dc
- Phoenix Contact MINI MCR Series Signal Conditioner Voltage Input 9.6 → 30V dc