Omron G9SE 24 V dc Safety Relay Dual Channel With 2 Safety Contacts and 1 Auxiliary Contact

  • RS Stock No. 890-3389
  • Mfr. Part No. G9SE-201-DC24
  • Brand Omron
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Omron G9SE Safety Relay

The G9SE safety relay from Omron is ideal for a variety of safety input devices such as emergency stop switches, door switches, and light curtains. The screw-less terminals on the front of the G9SE makes installation quick and easy, even in a small control panel where space is limited. Intuitive LED indicators on the safety relay show the operating status of safety inputs and outputs, enabling faster and more accurate troubleshooting when the equipment stops.

Easy and reliable installation and maintenance
Simple wiring using screw-less terminals
Faster troubleshooting with status indicators
Applicable safety standards
OFF-delayed safety output models are also available (stock no. 890-3386 & 890-3395)
Slim design of only 17.5 or 22.5 mm saves space in the control panel

Standards

EN ISO 13849-1: PLe/Safety Category 4, IEC 62061: SIL3, EN81-1/-2.

Approvals

CE, UL, TUV, CCC.

G9SE Compact Safety Relay Model.

• Compact.
• Easy to install.
• Saves mounting space.
• Saves on installation cost.
• Reduced operational cost.
• Push-In Plus terminal block. (front facing)
• Easy wiring. (front)
• Screw-less terminals.
• 15 ms max response time.
• Diagnostic indicators. (LED)
• OFF-delayed safety input models available.
• 17.5 mm and 22.5 mm widths available.
• PNP Transistor output.
• State OFF delay function to PLe.

G9SE-201-DC24 Safety Relay.

• Safety output.
• Instantaneous DPST-NO (normally open).
• Auxiliary output 1 x Solid-state.
• Auxiliary output PNP transistor output load current 100 mA DC max.
• Rated voltage 24 V dc.
• Operating voltage range -15% to 10% of rated supply voltage.
• Rated power consumption 3 W max (loads not included).
• Safety output – Contact output
• OFF-delayed safety output 250 V ac, 5 A, 30 V dc, 5 A (resistive load)

Features and Benefits.

• Operating time (OFF to ON state) 100 ms Max. (normal operation)
• Operating time is the time taken for the safety contact to close (after safety inputs and feedback-reset input are turned ON). Bounce time is not included.
• Response time (ON to OFF state) 15 ms max.
• Accuracy OFF-delay time ±10% of set value.
• Input current 5 mA min.
• ON voltage 11 V dc max.
• OFF voltage 5 V dc max.
• OFF current 1 mA max.
• Cable length 100 m max.
• Reset input time 250ms min.
• Contact resistance 100 mΩ
• Mechanical durability 5000000 operations per min.
• Electrical durability 50000 operations min.
• Minimum applicable load 24 V dc, 4 mA.
• Over voltage category IEC/EN60664-1, safety output Class III, the others Class II.
• Protection IP20
• Insulation resistance 100 mΩ.
• Weight 150 g

Applications Include.

• Emergency stop switches.
• Door switches.
• Light curtains.
• Safety monitoring applications.

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Auxiliary Contacts 1
Function Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 2
Reset Method Automatic, Manual
Terminal Type Screw
Standards Met CAN C22.2 No.14, CSA C22.2 No.14, EN 62061 SIL3, EN 81-1, EN 81-2, EN ISO 13849-1: 2008 PL e Safety Category 4, EN/IEC 60947-5-1, GB 14048.5, IEC 62061 SIL 3, UL508
Depth 111.6mm
Length 144.5mm
Width 17.5mm
39 In stock - FREE next working day delivery available
Price Each
£ 78.85
(exc. VAT)
£ 94.62
(inc. VAT)
Units
Per unit
1 +
£78.85
Related Products
Professional range of IDEM VIPER Safety Relays with ...
Description:
Professional range of IDEM VIPER Safety Relays with pluggable terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and offer enhanced LED diagnostics and simplified wiring. Typical applications include safety interlock ...
Safety relay for emergency stop, safety doors, light ...
Description:
Safety relay for emergency stop, safety doors, light grid, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off delay/on delay 0.2 s to 60 s, 2 enabling current paths, US = 24 V DC, plug-in spring-cage terminal block. Low housing width of just 12.5mm Single and two-channel control2 enabling ...
"Safety features The safety relay meets the following ...
Description:
"Safety features The safety relay meets the following safety requirements The circuit is internally redundant with built-in self-monitoring. The safety device remains effective in the case of a component failure. The correct opening and closing of the safety device relays is tested automatically in each on-off cycle. "
The Schneider Electric safety module has application in ...
Description:
The Schneider Electric safety module has application in monitoring antivalent contacts and for emergency stop, guard and light curtain monitoring. Maximum response time on input open : 20ms Mounting support : 35mm symmetrical DIN rail Rated insulation voltage : 250V.