- RS Stock No.:
- 757-9304
- Mfr. Part No.:
- G9SB-3012-A AC/DC24
- Brand:
- Omron
View all Safety Relays
21 In stock - FREE next working day delivery available
7 available from Europe for delivery within 1 working day(s).
Price Each
£164.00
(exc. VAT)
£196.80
(inc. VAT)
Units | Per unit |
1 + | £164.00 |
- RS Stock No.:
- 757-9304
- Mfr. Part No.:
- G9SB-3012-A AC/DC24
- Brand:
- Omron
Legislation and Compliance
- COO (Country of Origin):
- CN
Product Details
G9SB, Safety Relays, Ultra Slim
The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact.
1 and 2 input channel units
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Manual and automatic reset units
Certification up to category 4 according to EN954-1 (depending on the application)
Can also be used with safety sensors F3SN, F3SH, F3S-B, F3STGR, F3SL, F3S-J
Conforms to EN standards (TUV approval)
Note
When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset operation
Approvals
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14
G9SB Ultra Slim Safety Relays.
Ultra slim relay module.
Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
Models with a width of 22.5 mm with 3 poles (safety contacts).
1 and 2 input channels.
Manual and automatic reset.
Can be DIN rail mounted.
Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
Conform to EN standards (TUV approval).
G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
Models with a width of 17.5 mm are available with 2 or 3 poles (safety contacts).
Models with a width of 22.5 mm with 3 poles (safety contacts).
1 and 2 input channels.
Manual and automatic reset.
Can be DIN rail mounted.
Relays with inverse inputs are used when inputting signals from 2 mechanical switches.
Relays with positive commons are used when inputting signals from a safety sensor or one mechanical switch.
Conform to EN standards (TUV approval).
G9SB-3010 is applied to safety category 3 of EN 954-1 if double breaking is used.
Applicable to Safety Sensors.
Model F3S-B
Model F3SH
Model F3S-J
Model F3SL
Model F3SN
Model F3S-TGR
Model F3SH
Model F3S-J
Model F3SL
Model F3SN
Model F3S-TGR
Model F3S-TGR Safety Sensors covers a range of articles available within Non-Contact Safety Switches, Light Curtains, Light Beams and Machine Guarding Accessories.
G9SB-3012-A AC/DC24 Slim Safety Relay.
Main contact 3PST-NO (normally open).
Auxiliary contact SPST-NC (normally closed).
2 Input channels
Auto-reset.
Input type Inverse.
Rated voltage 24 V ac/dc.
Operating voltage range 85% to 110% of the rated power supply voltage.
Power consumption 2 VA/1.7 W max.
Input current 30 mA max.
Resistive load
Rated load 250 V ac, 5 A. 30 V dc, 5 A.
Rated carry current 5 A.
Auxiliary contact SPST-NC (normally closed).
2 Input channels
Auto-reset.
Input type Inverse.
Rated voltage 24 V ac/dc.
Operating voltage range 85% to 110% of the rated power supply voltage.
Power consumption 2 VA/1.7 W max.
Input current 30 mA max.
Resistive load
Rated load 250 V ac, 5 A. 30 V dc, 5 A.
Rated carry current 5 A.
Features and Benefits.
Contact resistance 100 mΩ
Insulation resistance 100 MΩ mon (at 500 V dc)
Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
Shock resistance destruction 300 m/s².
Shock resistance malfunction 100 m/s²
Failure rate (P Level) (reference value) 5 V dc, 1 mA
Always turn OFF the G9SB before connecting an expansion unit.
If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
Stranded wire 0.2 to 2.5 mm²
Solid Wire 0.2 to 2.5 mm²
Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
Positive thermistor built onto the circuits detecting short breakdowns.
Weight 120 g
Insulation resistance 100 MΩ mon (at 500 V dc)
Vibration resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
Shock resistance destruction 300 m/s².
Shock resistance malfunction 100 m/s²
Failure rate (P Level) (reference value) 5 V dc, 1 mA
Always turn OFF the G9SB before connecting an expansion unit.
If mounting multiple units next to each other the rated current will be 3 A. (do not apply any higher currents)
Stranded wire 0.2 to 2.5 mm²
Solid Wire 0.2 to 2.5 mm²
Screw torque of 0.5 to 0.6 Nm. (incorrect screw tightening can result in a malfunction or generate heat).
Positive thermistor built onto the circuits detecting short breakdowns.
Weight 120 g
Applications Include.
Light curtain.
Light guard.
Light guard.
Specifications
Attribute | Value |
Supply Voltage | 24V ac/dc |
Number of Channels | 2 |
Safety Contacts | 3 |
Function | Emergency Stop |
Auxiliary Contacts | 1 |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
Depth | 112mm |
Series | G9SB |
Width | 23mm |
Length | 100mm |
Performance Level | e |