SICK STR1 Safety Switch Actuator Included, Vistal

Subtotal (1 unit)*

£151.91

(exc. VAT)

£182.29

(inc. VAT)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 05 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +£151.91

*price indicative

RS Stock No.:
285-4287
Mfr. Part No.:
STR1-SAFF0AC8
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Switch

Actuator Included

Yes

Safety Contacts

1

Housing Material

Vistal

Series

STR1

Contact AC Voltage

230V ac

IP Rating

IP67, IP69K

Switch Contact Current

100mA

Minimum Operating Temperature

-30°C

Contact DC Voltage

24V dc

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Length

18mm

Standards/Approvals

CE

Width

40mm

Number of Head Directions

5

Depth

26mm

COO (Country of Origin):
MY

SICK STR1 Series Safety Switch, IP67, Vistal Housing - STR1-SAFF0AC8


This safety switch is a non-contact RFID sensor designed to monitor guarded access points in industrial settings. It provides functional safety outputs with self-monitoring semiconductor outputs and auxiliary switching for complementary signalling. The unit is suitable for installations requiring immunity to moisture and high-pressure cleaning, and operates within a wide ambient temperature range for demanding production environments.

Features and Benefits:


• SIL3 safety integrity for high-risk applications
• PLe Category 4 meeting strict performance requirements
• Two safe semiconductor outputs with ≤100mA output current
• Active sensing on three surfaces enabling multi-directional actuation
• IP69K protection allowing high-pressure washdown resistance

Applications


• Suitable for machine-guard monitoring in manufacturing plants
• Ideal for food-industry washdown environments requiring IP69K
• Used with safety controllers for series-connection topologies
• Can be used for access control on automated packaging lines

What supply voltage range does it accept?


It accepts 24V DC within a supply tolerance of 19.2V DC to 28.8V DC.

How are diagnostics and series connection handled?


Diagnostics-capable series connection is available via the Flexi Loop and non-diagnostic connection via a T-connector.

What environmental ratings apply to the enclosure?


The housing is rated IP67 and additionally IP69K for protection against dust, immersion and high-pressure cleaning.

What indicators assist with status and fault diagnosis?


LED displays provide status indication and a diagnostics indicator conveys fault conditions.

How long is the mission time and what is the PFHD value?


The mission time is 20 years and the PFHD is 5.1 x 10⁻⁹.

Related links

Be the first to know about our latest products and offers

Email address

The personal information you provide to us when signing up to this mailing list will be processed in line with the Privacy Policy