ABB F200 RCCB, 25A, 2 Pole, 30mA, 230V ac
- RS Stock No.:
- 176-9632
- Mfr. Part No.:
- F202F-25/0.03
- Brand:
- ABB
Subtotal (1 unit)*
£337.22
(exc. VAT)
£404.66
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 3 unit(s) shipping from 27 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £337.22 |
*price indicative
- RS Stock No.:
- 176-9632
- Mfr. Part No.:
- F202F-25/0.03
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | ABB | |
Circuit Breaker Type | RCCB | |
Current Rating | 25A | |
Number of Poles | 2 | |
Trip Sensitivity | 30mA | |
Voltage Rating | 230V ac | |
Series | F200 | |
Reset Actuator Type | Toggle Switch | |
Overall Dimensions | 35 x 69 x 85mm | |
Earth Leakage Protection Type | A-APR | |
Overall Depth | 85mm | |
Overall Width | 69mm | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Mounting Style | DIN Rail Mount | |
Break Time | Time Delay | |
Overall Length | 35mm | |
Terminal Contact Type | Screw | |
Special Features | Earth Fault Safety Protection | |
Select all | ||
---|---|---|
Brand ABB | ||
Circuit Breaker Type RCCB | ||
Current Rating 25A | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Voltage Rating 230V ac | ||
Series F200 | ||
Reset Actuator Type Toggle Switch | ||
Overall Dimensions 35 x 69 x 85mm | ||
Earth Leakage Protection Type A-APR | ||
Overall Depth 85mm | ||
Overall Width 69mm | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Mounting Style DIN Rail Mount | ||
Break Time Time Delay | ||
Overall Length 35mm | ||
Terminal Contact Type Screw | ||
Special Features Earth Fault Safety Protection | ||
- COO (Country of Origin):
- IT
F202 Type F, RCCB in two poles with rated current 25-40-63A and sensitivity 30mA for the protection of single phase circuits.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR
this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.