Pico Technology TA058 Oscilloscope Probe, Active, Differential Type, 50MHz, 1:10
- RS Stock No.:
- 898-6769
- Mfr. Part No.:
- TA058
- Brand:
- Pico Technology
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 898-6769
- Mfr. Part No.:
- TA058
- Brand:
- Pico Technology
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Pico Technology | |
Probe Type | Active, Differential | |
Attenuation | 1:10 | |
Bandwidth | 50MHz | |
Maximum Common Mode Input Voltage | 600V | |
Model Number p | TA058 | |
Number of Probes | 2 | |
Safety Category | 600 V, CAT I ±700V | |
Select all | ||
---|---|---|
Brand Pico Technology | ||
Probe Type Active, Differential | ||
Attenuation 1:10 | ||
Bandwidth 50MHz | ||
Maximum Common Mode Input Voltage 600V | ||
Model Number p TA058 | ||
Number of Probes 2 | ||
Safety Category 600 V, CAT I ±700V | ||
- COO (Country of Origin):
- TW
Pico Technology Oscilloscope Probe
The Pico Technology TA058 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±700V. It can be used with a signal speed of up to 50MHz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.
Features and Benefits
Bandwidth is DC to 50MHz (–3dB)
Attenuation ratio is 10:1
Accuracy is ±1%
Input impedance is 1.6Mohm ll7pF each side to ground
Differential range is ±70V (DC + peak AC) or 70VRMS
Maximum differential is ±700 V (DC + peak AC) or 600VRMS
Common mode range is ±700V (DC + peak AC) or 600VRMS
Absolute maximum voltage is ±700V (DC + peak AC) or 600VRMS CAT I
Swing is ±7V into 5Kohm load
Offset (typical) is <±2mV
Noise (typical) is 0.7mVRMS
Source impedance is 50ohm
CMRR (typical) is 95dB at 60Hz and 60dB at 1MHz
Ambient operating temperature ranges between -10°C and 40°C
Power requirement 4xAA cells or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor
Attenuation ratio is 10:1
Accuracy is ±1%
Input impedance is 1.6Mohm ll7pF each side to ground
Differential range is ±70V (DC + peak AC) or 70VRMS
Maximum differential is ±700 V (DC + peak AC) or 600VRMS
Common mode range is ±700V (DC + peak AC) or 600VRMS
Absolute maximum voltage is ±700V (DC + peak AC) or 600VRMS CAT I
Swing is ±7V into 5Kohm load
Offset (typical) is <±2mV
Noise (typical) is 0.7mVRMS
Source impedance is 50ohm
CMRR (typical) is 95dB at 60Hz and 60dB at 1MHz
Ambient operating temperature ranges between -10°C and 40°C
Power requirement 4xAA cells or 6VDC/60mA mains adaptor or regulated 9VDC/40mA mains adaptor
Applications
Safe measurement in power circuit
Acquisition of low speed balanced differential signals found in serial communications buses
Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays
Signals in the milliV range from sensors and other instrumentation
Acquisition of low speed balanced differential signals found in serial communications buses
Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays
Signals in the milliV range from sensors and other instrumentation
Certifications
IEC-1010.1
IEC-1010.2-031 CAT III
Pollution Degree 2
IEC-1010.2-031 CAT III
Pollution Degree 2
Related links
- Pico Technology Oscilloscope Probe Differential Type 1:10
- Pico Technology TA057 Oscilloscope Probe Differential Type 1:20 BNC Connector
- RS PRO Oscilloscope Probe 50MHz 1:100
- Metrix MTX 1032-C Oscilloscope Probe 50MHz 1:100, BNC Connector
- Teledyne LeCroy AP30X Series AP034 Oscilloscope Probe Differential Type 1x, BNC Connector
- Teledyne LeCroy ZD Series ZD200 Oscilloscope Probe Differential Type 1:1
- Testec SI Series TT-SI 9010 Oscilloscope Probe Differential Type 1:100 BNC Connector
- Tektronix P52XXA Series P5200A Oscilloscope Probe 50MHz 1:500