HARTING Heavy Duty Power Connector Insert, 16 A, Han A Series Female, 10 Contacts

Bulk discount available

Subtotal (1 unit)*

£18.51

(exc. VAT)

£22.21

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 112 unit(s) ready to ship from another location
  • Plus 515 unit(s) shipping from 23 March 2026
  • Plus 250 unit(s) shipping from 15 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 - 9£18.51
10 - 24£17.76
25 - 49£17.01
50 +£16.26

*price indicative

RS Stock No.:
181-0892
Distrelec Article No.:
143-42-499
Mfr. Part No.:
09200102812
Brand:
HARTING
Find similar products by selecting one or more attributes.
Select all

Brand

HARTING

Current Rating

16 A

Product Type

Heavy Duty Power Connector Insert

Series

Han A

Sub Type

Connector Insert

Connector Gender

Female

For Use With

Heavy Duty Power Connector

Pole Format

10+E

Number of Rows

2

Voltage

600 V

Mount Type

Panel Mount

Manufacturer Size Code

10A

Standards/Approvals

No

Number of Contacts

10

Maximum Wire Size mm²

2.5mm²

Minimum Wire Size mm²

0.75mm²

Contact Material

Polycarbonate

Orientation

Straight

COO (Country of Origin):
RO

Han A® Inserts


Harting contact inserts have a wide range of uses. Inserts are selected according to the desired number of poles and voltage and current ratings.

Han A inserts options include:

1810482 – 09200042611, 4P+E pin insert,10A

1810498 – 09200042711, 4P+E socket insert,10A

1810858 – 09200032611, 3P+E pin insert,10A

1810870 – 09200032711, 3P+E socket insert,10A

1810886 – 09200102612, 10P+E pin insert,16A

1810892 – 09200102812, 10P+E socket insert,16A

1810915 – 09200162612, 16P+E pin insert,16A

1810937 – 09200162812, 16P+E socket insert,16A

Han A series Features:


• Slim construction

• Poles: 3-16 (screw connection)

Han A® 10A to 16A Screw Series


These Han A® inserts are available in 10A and 16A current ratings. They are intended for use typically with hoods and housing; RS stock Nos. 114-8024, 181-0662 and 181-0690 and the associated ranges. These hoods and housings are associated to a specific Harting 'Size' number.

Note

Two 16P + E inserts may be accommodated within a ’Size’ 32A housing (typical stock no 363-7964)

Approvals

UL, CSA, SEV

Warning

These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of wrong connection.