12V ac 1 Output Through Hole PCB Transformer, 36VA

  • RS Stock No. 732-0499
  • Mfr. Part No. VCM 36/1/12
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347248-01.gif
//media.rs-online.com/t_line/L7320547-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specifications
Attribute Value
Secondary Voltage Rating 12V ac
Power Rating 36VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 87.2mm
Width 60mm
Depth 48.5mm
Dimensions 87.2 x 60 x 48.5mm
Weight 750g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
17 In stock for FREE next working day delivery
Price Each
£ 14.90
(exc. VAT)
£ 17.88
(inc. VAT)
Units
Per unit
1 - 9
£14.90
10 - 24
£14.26
25 - 49
£13.09
50 +
£11.94
Related Products
Compact, open type control panel transformerFully shrouded screw ...
Description:
Compact, open type control panel transformerFully shrouded screw terminals with permanent markingDetailed product specification permanently marked on front of unitVA ratings compatible with available protection devicesDual standard primary winding 230 / 400Vac.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding capacitanceLow radiated noiseExtra fixing holes for secure board mountingStandard: EN60742, VDE ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.