Fluke 6500 PAT Tester, Class I, Class II Test Type With UKAS Calibration
- RS Stock No.:
- 797-6718
- Mfr. Part No.:
- FLUKE-6500-2 UK
- Brand:
- Fluke
Subtotal (1 unit)*
£1,963.77
(exc. VAT)
£2,356.52
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 3 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £1,963.77 |
*price indicative
- RS Stock No.:
- 797-6718
- Mfr. Part No.:
- FLUKE-6500-2 UK
- Brand:
- Fluke
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Fluke | |
Tester Type | Pass/Fail PAT | |
Test Type | Class I, Class II | |
Testing Method | Automatic, Manual | |
Download | Yes | |
Calibrated | UKAS | |
Model Number p | 6500 | |
Plug Type | Type G - British 3-pin | |
Power Source | Mains | |
Weight | 3kg | |
Height | 100mm | |
Length | 200mm | |
Maximum Operating Temperature | +40°C | |
Maximum Supply Voltage | 230V | |
Width | 275mm | |
Minimum Operating Temperature | 0°C | |
Minimum Supply Voltage | 110V | |
Select all | ||
---|---|---|
Brand Fluke | ||
Tester Type Pass/Fail PAT | ||
Test Type Class I, Class II | ||
Testing Method Automatic, Manual | ||
Download Yes | ||
Calibrated UKAS | ||
Model Number p 6500 | ||
Plug Type Type G - British 3-pin | ||
Power Source Mains | ||
Weight 3kg | ||
Height 100mm | ||
Length 200mm | ||
Maximum Operating Temperature +40°C | ||
Maximum Supply Voltage 230V | ||
Width 275mm | ||
Minimum Operating Temperature 0°C | ||
Minimum Supply Voltage 110V | ||
RoHS Status: Exempt
- COO (Country of Origin):
- RO
Fluke 6500-2 PAT Tester UK Version
The Fluke 6500-2 Portable appliance tester verifies the electrical safety and operation of portable appliances in accordance with relevant guidelines and regulations.
Features and Benefits
With powerful auto test capabilities and simplified controls, including one touch test routines, the Fluke 6500-2 PAT Tester increases the number of tests you can perform per day without compromising results
The Fluke 6500-2 is suitable for testing both 230 V and 110 V appliances,the 6500-2 model runs all the required safety tests: Earth bond low (low/high current, Insulation 500 V, 250 V, Leakage (PE current, touch current, substitute current), Can test 110 V appliances (earth bond, insulation) via the 110 V adapter kit
Integral QWERTY keyboard for rapid data entry
Memory for back-up data storage and USB port for transfer to PC
Large backlit graphics display
Pre-set, auto-test sequences for user convenience
Integral site, location and description codes for faster data processing
Memory review facility for more on-site control
Dedicated key for each test for one-touch testing
Pre-set pass/fail levels to save time
Large display for easy reading
Single mains socket for appliance connection
Separate IEC socket for easy mains/extension lead testing
Detachable test leads for quick field replacement
Integral carrying handle
Dimensions: 200 x 275 x 114 mm
Weight: 3.13 kg
The Fluke 6500-2 is suitable for testing both 230 V and 110 V appliances,the 6500-2 model runs all the required safety tests: Earth bond low (low/high current, Insulation 500 V, 250 V, Leakage (PE current, touch current, substitute current), Can test 110 V appliances (earth bond, insulation) via the 110 V adapter kit
Integral QWERTY keyboard for rapid data entry
Memory for back-up data storage and USB port for transfer to PC
Large backlit graphics display
Pre-set, auto-test sequences for user convenience
Integral site, location and description codes for faster data processing
Memory review facility for more on-site control
Dedicated key for each test for one-touch testing
Pre-set pass/fail levels to save time
Large display for easy reading
Single mains socket for appliance connection
Separate IEC socket for easy mains/extension lead testing
Detachable test leads for quick field replacement
Integral carrying handle
Dimensions: 200 x 275 x 114 mm
Weight: 3.13 kg
Test specifications
Power-on test
Earth bond test (Rpe)
Insulation test (RISO)
Touch current test
Substitute leakage current
RCD Test: trip current
RCD Test: trip time
Load/Leakage test: load current
Load/Leakage test: load power display range 230 V mains
Load/Leakage test: Leakage current
PELV test
Earth bond test (Rpe)
Insulation test (RISO)
Touch current test
Substitute leakage current
RCD Test: trip current
RCD Test: trip time
Load/Leakage test: load current
Load/Leakage test: load power display range 230 V mains
Load/Leakage test: Leakage current
PELV test
Standards
Complies with EN61010-1 3rd edition CAT II, 300 V, pol 2
Supplied with
Test Lead (found in hidden compartment in lid), test probe, crocodile clip, mains cord, storage case, quick reference guide, USB stick, USB cable, Users manual on CD.
Related links
- Fluke 6500 PAT Tester Class II Test Type With RS Calibration
- Fluke 6500 PAT Testing Kit Class II Test Type
- Fluke 6200 PAT Tester Class II Test Type With UKAS Calibration
- Fluke 6200 PAT Tester Class II Test Type With RS Calibration
- Fluke 6200 PAT Tester Class II Test Type
- Fluke 6200-2 PAT Testing Kit Class II Test Type With RS Calibration
- Megger PAT120-UK PAT Tester Class II Test Type With UKAS Calibration
- Seaward PrimeTest 50 UK PAT Tester Class II Test Type With UKAS Calibration