Fluke 8846A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - RS Calibrated
- RS Stock No.:
- 625-0475
- Mfr. Part No.:
- 8846A
- Brand:
- Fluke
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
£1,424.10
(exc. VAT)
£1,708.92
(inc. VAT)
- RS Stock No.:
- 625-0475
- Mfr. Part No.:
- 8846A
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Bench | |
| Model Number p | 8846A | |
| Display Type | Digital | |
| Calibrated | RSCAL | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature | |
| Absolute Maximum Resistance Measurement | 1GΩ | |
| Absolute Maximum DC Current Measurement | 10A dc | |
| Absolute Maximum DC Voltage Measurement | 1000V dc | |
| Absolute Maximum AC Current Measurement | 10A ac | |
| Absolute Maximum AC Voltage Measurement | 1000V ac | |
| Absolute Maximum Capacitance Measurement | 100mF | |
| Absolute Maximum Temperature Measurement | +600°C | |
| Maximum Frequency | 300kHz | |
| DC Current Measurement Resolution | 0.0001µA dc | |
| AC Current Measurement Resolution | 0.0001µA ac | |
| AC Voltage Measurement Resolution | 0.0001mV ac | |
| Resistance Measurement Resolution | 10µΩ | |
| DC Voltage Measurement Resolution | 0.0001mV dc | |
| Capacitance Measurement Resolution | 1pF | |
| Temperature Measurement Resolution | 0.001°C | |
| Safety Category Level | CAT I, CAT II | |
| Safety Category Voltage | 600 V, 1000V | |
| Length | 297mm | |
| Best DC Current Accuracy | ±0.15% + 0.008 | |
| Weight | 3.6kg | |
| Best Resistance Measurement Accuracy | ±2% + 0.01 | |
| Minimum Operating Temperature | 0°C | |
| Best Capacitance Measurement Accuracy | ±4.2 % | |
| Height | 88mm | |
| Best Temperature Measurement Accuracy | ±0.22 % | |
| Dimensions | 297 x 217 x 88mm | |
| Width | 217mm | |
| Best AC Current Accuracy | ±0.35% + 0.7 | |
| Maximum Operating Temperature | +55°C | |
| Best DC Voltage Accuracy | ±0.0041% + 0.001 | |
| Best AC Voltage Accuracy | ±4% + 0.375 | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Bench | ||
Model Number p 8846A | ||
Display Type Digital | ||
Calibrated RSCAL | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature | ||
Absolute Maximum Resistance Measurement 1GΩ | ||
Absolute Maximum DC Current Measurement 10A dc | ||
Absolute Maximum DC Voltage Measurement 1000V dc | ||
Absolute Maximum AC Current Measurement 10A ac | ||
Absolute Maximum AC Voltage Measurement 1000V ac | ||
Absolute Maximum Capacitance Measurement 100mF | ||
Absolute Maximum Temperature Measurement +600°C | ||
Maximum Frequency 300kHz | ||
DC Current Measurement Resolution 0.0001µA dc | ||
AC Current Measurement Resolution 0.0001µA ac | ||
AC Voltage Measurement Resolution 0.0001mV ac | ||
Resistance Measurement Resolution 10µΩ | ||
DC Voltage Measurement Resolution 0.0001mV dc | ||
Capacitance Measurement Resolution 1pF | ||
Temperature Measurement Resolution 0.001°C | ||
Safety Category Level CAT I, CAT II | ||
Safety Category Voltage 600 V, 1000V | ||
Length 297mm | ||
Best DC Current Accuracy ±0.15% + 0.008 | ||
Weight 3.6kg | ||
Best Resistance Measurement Accuracy ±2% + 0.01 | ||
Minimum Operating Temperature 0°C | ||
Best Capacitance Measurement Accuracy ±4.2 % | ||
Height 88mm | ||
Best Temperature Measurement Accuracy ±0.22 % | ||
Dimensions 297 x 217 x 88mm | ||
Width 217mm | ||
Best AC Current Accuracy ±0.35% + 0.7 | ||
Maximum Operating Temperature +55°C | ||
Best DC Voltage Accuracy ±0.0041% + 0.001 | ||
Best AC Voltage Accuracy ±4% + 0.375 | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- US
8845A & 8846A 6.5 Digit Precision Multimeter
The 8846A includes a USB device port to connect standard USB memory storage devices. Both instruments include an RS-232, IEEE-488 and Ethernet interface as standard, with popular DMM emulation modes which make system integration a simple task.
Features and Benefits:
These digital multimeters perform the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps. Basic V DC accuracy of up to 0.0024%, 10 A current range, and a wide ohms range give you an unbeatable combination of measurement capability.
You can also use the 8845A and 8846A to measure frequency and period. In addition, the 8846A measures temperature and capacitance. The functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters utility even more with their graphical display modes, including Trendplot™ paperless recorder mode, statistics and histograms—features you wont find on other multimeters.
Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the 8845A and 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service
FlukeView® Software
Instrument programming drivers, DLL files and support information are included to get your test system up and running as quickly as possible.
The Fluke 8845A/8846A ship with a free copy of FlukeView Basic. Transfer data points from your meter to your PC and use the two standard, noncustomizable forms to display your readings in table or graphical form. For a larger array of forms or to use FlukeView Forms Designer to customize your forms, upgrade to FlukeView Forms version 3.0 with FVF-UG.
Supplied with
FlukeView® Forms – Basic for 8845A/8846A
Mains lead
Spare mains fuse
Programmer & users manuals (CD-ROM)
FLUKE Multimeter, 100mV to 1000V AC/DC Voltage Measurement Range, -200°C to +600°C Temperature Measurement Range - 8846A
• Broad temperature measurement range of -200°C to +600°C to take readings in demanding environments
• Compact dimensions of 88 (H) x 217 (W) x 297mm (D) take up minimal space in your setup
Applications
• Industrial automation
• Power generation plants