Better World
Schneider Electric LUC DOL Starter, DOL, 690V ac, 3 kW, 3 Phase, IP40
- RS Stock No.:
- 272-454
- Distrelec Article No.:
- 136-22-697
- Mfr. Part No.:
- LUCA05FU
- Brand:
- Schneider Electric
Subtotal (1 unit)*
£75.09
(exc. VAT)
£90.11
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 5 unit(s) ready to ship from another location
- Plus 8 unit(s) shipping from 28 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £75.09 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 272-454
- Distrelec Article No.:
- 136-22-697
- Mfr. Part No.:
- LUCA05FU
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | DOL Starter | |
| Power Rating | 3kW | |
| Sub Type | DOL | |
| Number of Phases | 3 | |
| Current Rating | 32A | |
| IP Rating | IP40 | |
| Number of Poles | 3 | |
| Overall Length | 66mm | |
| Maximum Voltage | 690V ac | |
| Hazardous Area Certification | ATEX | |
| Overall Width | 45mm | |
| Standards/Approvals | CSA C22.2 No. 14 type E, UL 508 Type E, IEC 60947-6-2, EN 60947-6-2 | |
| Overall Depth | 60mm | |
| Series | LUC | |
| Better World Product | Yes | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type DOL Starter | ||
Power Rating 3kW | ||
Sub Type DOL | ||
Number of Phases 3 | ||
Current Rating 32A | ||
IP Rating IP40 | ||
Number of Poles 3 | ||
Overall Length 66mm | ||
Maximum Voltage 690V ac | ||
Hazardous Area Certification ATEX | ||
Overall Width 45mm | ||
Standards/Approvals CSA C22.2 No. 14 type E, UL 508 Type E, IEC 60947-6-2, EN 60947-6-2 | ||
Overall Depth 60mm | ||
Series LUC | ||
Better World Product Yes | ||
RoHS Status: Exempt
Schneider Electric LUC Series DOL Starter, 5A Current, 3kW Power - LUCA05FU
This DOL starter is a Compact direct-on-line control unit designed to start and protect 3-phase motors in industrial installations. It integrates thermal-magnetic overload and short-circuit protection with phase loss and imbalance monitoring, and is intended for plug-in use on compatible power bases in automation and electrical control panels.
Features & Benefits
• 1.25 to 5A adjustable current protects motor windings
• 3kW at 690V AC delivers high-voltage motor starting capacity
• Class10 thermal release offers time-delayed overload response
• 110 to 240V AC or 110 to 220V DC Coil for flexible control supply
• ATEX certified for use in hazardous-area installations
• IP20 front and IP40 front-outside protection for panel mounting
• 3kW at 690V AC delivers high-voltage motor starting capacity
• Class10 thermal release offers time-delayed overload response
• 110 to 240V AC or 110 to 220V DC Coil for flexible control supply
• ATEX certified for use in hazardous-area installations
• IP20 front and IP40 front-outside protection for panel mounting
Applications
• Suitable for starting 3-phase motors up to 3kW at 690V AC
• Ideal for control panels requiring hazardous-area compliant starters
• used with plug-in power bases such as LUB12 and LUB32
• Can be used for reversing contactor to breaker assemblies in motor control
• Suitable for machinery where phase-failure protection is required
• Ideal for control panels requiring hazardous-area compliant starters
• used with plug-in power bases such as LUB12 and LUB32
• Can be used for reversing contactor to breaker assemblies in motor control
• Suitable for machinery where phase-failure protection is required
What control supply voltages will operate the unit?
It accepts 110 to 240V AC and 110 to 220V DC with operation limits of 88 to 264V AC and 88 to 242V DC.
How quickly does it operate during switching events?
Typical operating times are 50 MS to close and 35 MS to open on compatible bases.
What environmental conditions can it tolerate in service?
It operates between -25 to 70°C, stores between -40 to 85°C, and is rated for altitudes up to 2000 m.
Which insulation and impulse voltage ratings apply to the control and main circuits?
Rated insulation voltage is 690V with a 6 kV impulse withstand Value and 400V SELV separation between circuits.
How does it behave electrically under overload trip?
The tripping threshold is 14.2xIr ±20% with thermal class 10 performance across 40 to 60 Hz.
Note
'For use with' refers to a compatible power base in amps.
Warning
Schneider are in the process of amending the colour of the TeSys range, from White to Black. This means that the stock you receive could be either of these colours. Please be assured that the colour change in no way affects the Fit, Form or Function of the product.
Related links
- Schneider Electric TeSys U, 690V ac
- Schneider Electric TeSys U Advanced Motor Starter 0.09 kW IP20
- Schneider Electric TeSys U, 690V
- Schneider Electric TeSyS U Advanced Motor Starter 15 kW IP40
- Schneider Electric TeSyS U Advanced Motor Starter 7.5 kW IP20, IP40
- Schneider Electric TeSyS U Motor Controller 7.5 kW IP20
- Schneider Electric TeSyS U Advanced Motor Starter 0.09 kW IP20, IP40
- Schneider Electric TeSyS U Motor Controller 18.5 kW IP20