Dold Frequency Monitoring Relay, SPDT, DIN Rail
- RS Stock No.:
- 181-2793
- Mfr. Part No.:
- MK9143N.38 +/-5Hz UH=DC24V tv=0-20s tan=0-30s
- Brand:
- Dold
Subtotal (1 unit)*
£226.58
(exc. VAT)
£271.90
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 21 November 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £226.58 |
*price indicative
- RS Stock No.:
- 181-2793
- Mfr. Part No.:
- MK9143N.38 +/-5Hz UH=DC24V tv=0-20s tan=0-30s
- Brand:
- Dold
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Dold | |
Monitoring Application | Frequency | |
Contact Configuration | SPDT | |
Mounting Type | DIN Rail | |
Time Delay | 0 → 20 s, 0 → 30s | |
Frequency Sensing Range | ±5Hz | |
Series | MK9143N | |
Frequency Sensitivity | Overfrequency, Underfrequency | |
Dimensions | 97 x 22.5 x 90mm | |
Width | 22.5mm | |
Minimum Frequency Sensed | -5Hz | |
Maximum Operating Temperature | +60°C | |
Height | 90mm | |
Terminal Type | Screw | |
Minimum Operating Temperature | -20°C | |
Length | 97mm | |
Maximum Frequency Sensed | +5Hz | |
Operating Temperature Range | +60°C | |
Select all | ||
---|---|---|
Brand Dold | ||
Monitoring Application Frequency | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay 0 → 20 s, 0 → 30s | ||
Frequency Sensing Range ±5Hz | ||
Series MK9143N | ||
Frequency Sensitivity Overfrequency, Underfrequency | ||
Dimensions 97 x 22.5 x 90mm | ||
Width 22.5mm | ||
Minimum Frequency Sensed -5Hz | ||
Maximum Operating Temperature +60°C | ||
Height 90mm | ||
Terminal Type Screw | ||
Minimum Operating Temperature -20°C | ||
Length 97mm | ||
Maximum Frequency Sensed +5Hz | ||
Operating Temperature Range +60°C | ||
- COO (Country of Origin):
- DE
Monitoring of local generator sets and voltage supplies
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
For precise frequency measuring with fast response time
High disturbance immunity
Separately adjustable trip points and separate outputs for over-
and under frequency (1 or 2 c/o each)
MK 9143N / MH 9143:
Trip points adjustable precisely and reproducible on 10 step rotational switch in the range of ± 0,1 Hz to ± 5 Hz related to 50 or 60 Hz
Nominal frequency 50 or 60 Hz selectable
Fixed hysteresis optimised for trip point
As option one common output for under and over frequency Window-mode (MK 9143N/400 / MH 9143/400)
Variable alarm value in the range of 45 to 65 Hz
Hysteresis adjustable for under- and over frequency separatelyadjustable 0 …20% Common output for under and over frequency Window-mode can be selected
Start up delay 0…30 s selectable
Manual or auto reset selectable
Output relay energized or de-energized on trip selectable for
over frequency
Output relay de-energized on trip for under frequency
Universal frequency measuring input for AC 40 … 550V
Several options for auxiliary supply
LED indicators for auxiliary supply, input frequency, over and
under frequency alarm
Related links
- Dold Frequency Monitoring Relay DIN Rail
- Dold Frequency Monitoring Relay 15 → 280V ac, DIN Rail
- Dold 12 A MK 9397N Motor Load Monitor, 12 To 400 V ac
- Dold Monitoring Relay 2NO/1NC DIN Rail
- Dold Monitoring Relay 24 → 400V ac/dc, DIN Rail
- Dold Multifunction Monitoring Relay SPDT DIN Rail
- Dold Speed Monitoring Relay DIN Rail
- Dold Standstill Monitoring Relay 3 Phase DIN Rail