Dold Standstill Monitoring Relay With 3NO/NC Contacts, 24 V dc Supply Voltage

  • RS Stock No. 181-2782
  • Mfr. Part No. LH5946.48/61 20-400mV UH=DC24V 0,2-6s
  • Brand Dold
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Safe standstill detection on 3and single-phase motors
No external sensors necessary
Independent of direction
Broken wire detection
Forcibly guided safety contacts:
3 NO contacts, 1 NC contact for AC 250 V
2 semiconductor monitoring outputs
1 monitoring output (NO contact)
Adjustable voltage setting
Adjustable standstill time delay
LED indicators for standstill, event of line breakage and operation voltage
Suitable for operation with inverters
Width 45 mm
Advantages / Customer benefit
Without sensor and safe
Fast reaction time
Easy to retrofit
Combined with Interlock SAFEMASTER STS

Specifications
Attribute Value
Monitoring Application Standstill
Supply Voltage 24 V dc
Contact Configuration 3NO/NC
Voltage Sensing Range 20 → 400 mV
Time Delay 0.2 → 6 s
Terminal Type Screw
Mounting Type DIN Rail
Height 90mm
Dimensions 45 x 121 x 90 mm
Maximum Operating Temperature +60°C
Operating Temperature Range -25 → +60 °C
Minimum Voltage Sensed 20 mV
Width 121mm
Series LH5946
Minimum Operating Temperature -25°C
Length 45mm
4 In stock for delivery within 1 working days
Price Each
£ 438.52
(exc. VAT)
£ 526.22
(inc. VAT)
Units
Per unit
1 +
£438.52
Not available for guaranteed pre 9am/10am delivery
Related Products
Monitoring of local generator sets and voltage supplies ...
Description:
Monitoring of local generator sets and voltage supplies For precise frequency measuring with fast response time High disturbance immunity Separately adjustable trip points and separate outputs for over-and under frequency (1 or 2 c/o each)MK 9143N / MH 9143:Trip points adjustable precisely and reproducible on 10 step rotational switch in ...
Multifunction measuring relay Voltage monitoring (1- and 3-phase)Current ...
Description:
Multifunction measuring relay Voltage monitoring (1- and 3-phase)Current monitoring Frequency monitoring Power factor cos phi Phase sequence, phase failure, asymmetry Effective-, reactive- and apparent power Start up delay, on delay Adjustable hysteresis 0.2 ... 50 % of response value Manual reset LCD for indication of the measuring values Relay output ...
The MK9052 motor protection relay is used to ...
Description:
The MK9052 motor protection relay is used to prevent thermal overloads in motors (for example as caused by high switching frequencies, heavy start-up loads, single phase operation, interrupted cooling, high ambient temperature).Special thermistors (PTC resistors) developed specifically for motor protection are used as temperature sensors. Up to 6 sensors can ...
The AI898 insulation monitor displays the insulation resistance ...
Description:
The AI898 insulation monitor displays the insulation resistance of unearthed direct current networks to earth. It does not detect symmetrical earth faults. In practice, these faults are generally insignificant.The AI898 works on the quiescent current principle, for example when the auxiliary voltage is applied to terminals A1 → A2 the ...