Eaton EMR4 Current Monitoring Relay With DPDT Contacts, 220 → 240 V ac, 1 Phase

  • RS Stock No. 102-6140
  • Mfr. Part No. 106944
  • Brand Eaton
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

EMR4 Series

Professional range of Eaton current monitoring relays from the EMR4 series. The main function of the relays is the monitoring of single phase AC and DC networks. The relays are designed to cover a wide range of applications in electrical switchgear technology such as multifunctional 3 phase monitors and earth leakage monitors.

Test button
LED status indication

Eaton Monitoring Relay

Specifications
Attribute Value
Monitoring Application Current
Supply Voltage 220 → 240 V ac
Contact Configuration DPDT
Electrical Phase 1
Current Sensitivity Overcurrent, Undercurrent
Minimum Current Sensed 0.3 (B1) A, 1 (B2) A, 3 (B3) A
Maximum Current Sensed 1.5 (B1) A, 5 (B2) A, 15 (B3) A
Time Delay 0.1 → 30 s
Dimensions 22.5 x 78 x 100 mm
Minimum Operating Temperature -20°C
Standards Met CE Certified, CSA-22.2, EN 55022, IEC 255-6, IEC 60947-5-1, IEC 664, IEC 947-1, IEC/EN 60068-2-30, IEC/EN 60255-21-1, IEC/EN 60255-21-2, IEC/EN 60255-5, IEC/EN 60255-6, IEC/EN 60947-1, IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN 61000-4-4, IEC/EN 61000-4-6, IEC/EN 61000-4-9, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL, UL 508, UL Listed, VDE 0110, 2004/108/EC, 2006/95/EC, 3211-03
Number of Poles 1
Height 100mm
Series EMR4
Current Range 0.3 → 1.5 (B1) A, 1 → 5 (B2) A, 3 → 15 (B3) A
Terminal Type Screw
Width 78mm
Maximum Operating Temperature +60°C
Operating Temperature Range -20 → +60 °C
Mounting Type DIN Rail
Length 22.5mm
1 In stock for FREE next working day delivery
Price Each
£ 174.43
(exc. VAT)
£ 209.32
(inc. VAT)
Units
Per unit
1 +
£174.43
Related Products
For single and 3-phase AC-systems up to 0 ...
Description:
For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz Monitors also disconnected voltage systems Adjustable tripping value RALof 5 ... 100 kΩDe-energized on trip Auxiliary voltage, measuring circuit and output contacts are galvanically separated Manual and auto reset With test and reset button ...
Features• According to IEC/EN 61 557-8• For single ...
Description:
Features• According to IEC/EN 61 557-8• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz• Monitors also disconnected voltage systems• Adjustable tripping value RALof 5 ... 100 kΩ• De-energized on trip• Auxiliary voltage, measuring circuit and output contacts are galvanically separated• Manual and ...
Application: 1-phase undercurrent monitoring in three-phase and alternating ...
Description:
Application: 1-phase undercurrent monitoring in three-phase and alternating current networks4 measurement ranges from 0.1 → 15 A without an additional current transducer (programmable via rotary control)Fixed hysteresis Adjustable switching delay Rest current principle LED displays: applied voltage, activated output relay Auxiliary voltage 230 Vac Auxiliary circuit and measuring circuit galvanically ...
Use: overcurrent monitoring in DC and AC current ...
Description:
Use: overcurrent monitoring in DC and AC current networks Four measurement ranges that can be set via a rotary switch Adjustable response value, fixed hysteresis Adjustable switching delay Rest current principle LED display for associated auxiliary voltage and activated output relay230 VAC auxiliary voltage Auxiliary and measurement ranges, galvanically isolated ...