Better World
ABB System Pro M Compact S200 MCB, 1P, 20A Curve D, 253V AC, 72V DC, 6 kA Breaking Capacity
- RS Stock No.:
- 527-9481
- Mfr. Part No.:
- 2CDS251001R0201 S201-D20
- Brand:
- ABB
Subtotal (1 unit)*
£17.22
(exc. VAT)
£20.66
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 20 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £17.22 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 527-9481
- Mfr. Part No.:
- 2CDS251001R0201 S201-D20
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 1 | |
| Current Rating | 20A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 253V | |
| Rated DC Voltage | 72V | |
| Breaking Capacity at Maximum Voltage Rating | 6 kA | |
| Range | System Pro M Compact | |
| Series | S200 | |
| Circuit Breaker Type | MCB | |
| Width | 17.5mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 76mm | |
| Model Number | S201-D20 | |
| Better World Claim | Designed for disassembly | |
| Better World Product | Yes | |
Select all | ||
|---|---|---|
Brand ABB | ||
Number of Poles 1 | ||
Current Rating 20A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 253V | ||
Rated DC Voltage 72V | ||
Breaking Capacity at Maximum Voltage Rating 6 kA | ||
Range System Pro M Compact | ||
Series S200 | ||
Circuit Breaker Type MCB | ||
Width 17.5mm | ||
Mounting Style DIN Rail Mount | ||
Depth 76mm | ||
Model Number S201-D20 | ||
Better World Claim Designed for disassembly | ||
Better World Product Yes | ||
RoHS Status: Exempt
- COO (Country of Origin):
- DE
ABB S200 Series MCB, 20A, 6kA Breaking Capacity (at Maximum Voltage Rating) - 2CDS251001R0201 S201-D20
This miniature circuit breaker provides effective electrical protection in commercial and industrial environments. It delivers essential functions such as overload and short circuit protection, contributing to a safe and dependable electrical system. Its durable design accommodates various applications, making it a necessary element for any electrical installation.
Features & Benefits
• Current limiting device enhances system safety
• Type D characteristic offers efficient short circuit protection
• Dual tripping mechanisms ensure consistent performance
• Compatible with DIN rail for straightforward installation
• Compact size conserves valuable space in control panels
• Designed for disassembly to promote sustainability
• Type D characteristic offers efficient short circuit protection
• Dual tripping mechanisms ensure consistent performance
• Compatible with DIN rail for straightforward installation
• Compact size conserves valuable space in control panels
• Designed for disassembly to promote sustainability
Applications
• Utilised in commercial electrical systems requiring circuit protection
• Suitable for industrial installations needing reliable overload safety
• Ideal for automation applications where electrical integrity is vital
• Employed in control panels to protect sensitive equipment
• Suitable for industrial installations needing reliable overload safety
• Ideal for automation applications where electrical integrity is vital
• Employed in control panels to protect sensitive equipment
What types of tripping mechanisms are included?
It features both delayed thermal and electromechanical tripping mechanisms for effective protection.
How does this device adapt to different environments?
It operates efficiently across a broad temperature range from -25 to +55°C.
Can this circuit breaker be easily integrated into existing systems?
Yes, it is designed for DIN rail mounting, allowing easy installation and integration.
Is there a specific installation procedure required?
Installation should adhere to standard electrical practices and guidelines for mounting on a DIN rail.
What should be considered for maintenance?
Routine inspections are recommended to verify proper functionality and inspect for signs of wear.
Standards
BS EN 60898
ABB System Pro M Single & Double Pole MCB's
Note
The Classic & System pro M product cannot be intermixed and do not share common accessories. System pro M products can only be fitted to new style Protecta distribution boards,see typically stock no. 539-1553.
Related links
- ABB System Pro M Compact S200 MCB 20A Curve K 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 20A Curve B 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 20A Curve C 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 6A Curve D 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 10A Curve D 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 25A Curve D 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 16A Curve D 72V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 40A Curve D 72V DC, 6 kA Breaking Capacity