ABB SU 200 M Circuit Breaker, 2P, 25A Curve K, 440V AC, 96V DC, 15 kA Breaking Capacity
- RS Stock No.:
- 287-6396
- Distrelec Article No.:
- 303-11-523
- Mfr. Part No.:
- 2CDS272337R0517
- Brand:
- ABB
Subtotal (1 unit)*
£94.64
(exc. VAT)
£113.57
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £94.64 |
*price indicative
- RS Stock No.:
- 287-6396
- Distrelec Article No.:
- 303-11-523
- Mfr. Part No.:
- 2CDS272337R0517
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | ABB | |
Number of Poles | 2 | |
Current Rating | 25A | |
Tripping Characteristics | Type K | |
Rated AC Voltage | 440V | |
Rated DC Voltage | 96V | |
Breaking Capacity at Maximum Voltage Rating | 15 kA | |
Series | SU 200 M | |
Select all | ||
---|---|---|
Brand ABB | ||
Number of Poles 2 | ||
Current Rating 25A | ||
Tripping Characteristics Type K | ||
Rated AC Voltage 440V | ||
Rated DC Voltage 96V | ||
Breaking Capacity at Maximum Voltage Rating 15 kA | ||
Series SU 200 M | ||
- COO (Country of Origin):
- DE
The ABB Miniature Circuit Breaker is designed for reliable circuit protection with a tripping characteristic of K. It offers a rated current of 25 A and a rated short-circuit capacity of 11.2 kA at 400 V AC. With various technical standards compliance and a compact design, this circuit breaker is a versatile choice for electrical systems.
Rated operational voltage of 440 V AC according to IEC standards
Dielectric test voltage of 2 kV for enhanced safety
Impulse withstand voltage of 4 kV for protection against sudden voltage surges
Energy limiting Class 3 designation for efficient power management
Rated insulation voltage of 440 V for reliable performance
Mechanical endurance of 20000 cycles for long-lasting use
Dielectric test voltage of 2 kV for enhanced safety
Impulse withstand voltage of 4 kV for protection against sudden voltage surges
Energy limiting Class 3 designation for efficient power management
Rated insulation voltage of 440 V for reliable performance
Mechanical endurance of 20000 cycles for long-lasting use
Related links
- ABB SU 200 M Circuit Breaker 4A Curve K 96V DC, 15 kA Breaking Capacity
- ABB SU 200 M Circuit Breaker 15A Curve K 96V DC, 15 kA Breaking Capacity
- ABB SU 200 M Circuit Breaker 10A Curve C 96V DC, 15 kA Breaking Capacity
- ABB SU 200 M Circuit Breaker 8A Curve K 48V DC, 15 kA Breaking Capacity
- ABB SU 200 M Circuit Breaker 10A Curve C 15 kA Breaking Capacity
- ABB SU200 M MCB 25A Curve C 96V DC, 15 kA Breaking Capacity
- ABB SU200 M MCB 200mA Curve K 96V DC, 15 kA Breaking Capacity
- ABB SU200 M MCB 500mA Curve K 96V DC, 15 kA Breaking Capacity