ABB S-ARC1 MCB, 1+N, 20A Curve C, 240V AC, 6 kA Breaking Capacity
- RS Stock No.:
- 175-9930
- Mfr. Part No.:
- 2CSA255901R9204 S-ARC1 C20
- Brand:
- ABB
Subtotal (1 unit)*
£163.62
(exc. VAT)
£196.34
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 15 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £163.62 |
*price indicative
- RS Stock No.:
- 175-9930
- Mfr. Part No.:
- 2CSA255901R9204 S-ARC1 C20
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | ABB | |
Number of Poles | 1+N | |
Current Rating | 20A | |
Tripping Characteristics | Type C | |
Rated AC Voltage | 240V | |
Breaking Capacity at Maximum Voltage Rating | 6 kA | |
Series | S-ARC1 | |
Length | 85mm | |
Width | 35mm | |
Mounting Style | DIN Rail Mount | |
Depth | 69mm | |
Model Number | S-ARC1 C20 | |
Tripping Mechanism | Thermal-Magnetic | |
Reset Actuator Type | Toggle Switch | |
Terminal Contact Type | Screw | |
Select all | ||
---|---|---|
Brand ABB | ||
Number of Poles 1+N | ||
Current Rating 20A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V | ||
Breaking Capacity at Maximum Voltage Rating 6 kA | ||
Series S-ARC1 | ||
Length 85mm | ||
Width 35mm | ||
Mounting Style DIN Rail Mount | ||
Depth 69mm | ||
Model Number S-ARC1 C20 | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Terminal Contact Type Screw | ||
- COO (Country of Origin):
- IT
S-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated MCB in two modules, for the protection against short-circuit currents, overload, earth arc faults, parallel arc faults and series arc faults. Integrated with an MCB in 6kA and 10kA breaking capacity, S-ARC1 and S-ARC1 M offer protection against over currents and arc faults in only two modules width.
Offers protection against:
Overload
Short-circuit
Earth arc fault
Parallel arc fault
Series arc fault
Overvoltage (higher than 275 V)
Application benefits:
Easy cross-wiring and easy installation with System pro M compact® busbars without any extra cables
LED for an easy troubleshooting of the network
Test button to verify the correct working
conditions of the device
Continuous internal self-test
Overload
Short-circuit
Earth arc fault
Parallel arc fault
Series arc fault
Overvoltage (higher than 275 V)
Application benefits:
Easy cross-wiring and easy installation with System pro M compact® busbars without any extra cables
LED for an easy troubleshooting of the network
Test button to verify the correct working
conditions of the device
Continuous internal self-test
Related links
- ABB S-ARC1 M MCB 20A Curve C 10 kA Breaking Capacity
- ABB S-ARC1 MCB 20A Curve B 6 kA Breaking Capacity
- ABB S-ARC1 M MCB 20A Curve B 10 kA Breaking Capacity
- ABB S-ARC1 MCB 13A Curve C 6 kA Breaking Capacity
- ABB S-ARC1 MCB 16A Curve C 6 kA Breaking Capacity
- ABB S-ARC1 MCB 10A Curve C 6 kA Breaking Capacity
- ABB S-ARC1 MCB 6A Curve C 6 kA Breaking Capacity
- ABB S-ARC1 M MCB 10A Curve C 10 kA Breaking Capacity