Allen Bradley 1492 1492-SPM MCB, 2P, 63A Curve C, 277V AC, 96V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 125-1478
- Mfr. Part No.:
- 1492-SPM2C630
- Brand:
- Allen Bradley
Subtotal (1 unit)*
£68.35
(exc. VAT)
£82.02
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- 1 unit(s) shipping from 24 October 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £68.35 |
*price indicative
- RS Stock No.:
- 125-1478
- Mfr. Part No.:
- 1492-SPM2C630
- Brand:
- Allen Bradley
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Allen Bradley | |
Number of Poles | 2 | |
Current Rating | 63A | |
Tripping Characteristics | Type C | |
Rated AC Voltage | 277 V, 480V | |
Rated DC Voltage | 96V | |
Breaking Capacity at Maximum Voltage Rating | 10 kA | |
Range | 1492 | |
Series | 1492-SPM | |
Circuit Breaker Type | MCB | |
Width | 75mm | |
Length | 35mm | |
Mounting Style | DIN Rail Mount | |
Depth | 88mm | |
Reset Actuator Type | Toggle Switch | |
Break Time | Instantaneous | |
Application | General Purpose | |
Tripping Mechanism | Thermal-Magnetic | |
Terminal Contact Type | Screw | |
Select all | ||
---|---|---|
Brand Allen Bradley | ||
Number of Poles 2 | ||
Current Rating 63A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 277 V, 480V | ||
Rated DC Voltage 96V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range 1492 | ||
Series 1492-SPM | ||
Circuit Breaker Type MCB | ||
Width 75mm | ||
Length 35mm | ||
Mounting Style DIN Rail Mount | ||
Depth 88mm | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
Application General Purpose | ||
Tripping Mechanism Thermal-Magnetic | ||
Terminal Contact Type Screw | ||
- COO (Country of Origin):
- DE
Allen Bradley 1492 SP Series Miniature Circuit Breakers – Type C
Experience high performance and exceptional protection for electrical circuits with the general purpose 1492-SPM Type C Miniature Circuit Breakers by Allen Bradley.
These 1492-SPM MCBs have type C tripping and fast breaking time to provide a higher level of safety for your application. They include screw terminals, are IP20 finger safe, and can be DIN rail mounted for optimal convenience. They are current-limiting and are available in 1, 2 or 3 pole versions, offering more versatility to meet your requirements. They also have dual terminals for wiring and bus bar flexibility. These units have excellent shock and vibration resistance which helps to prevent nuisance tripping, avoiding unnecessary downtime. Up to six accessories can be installed on the same circuit breaker to enable easy optimisation of your safety system.
Type C MCBs are suitable for use in commercial and light industrial applications, such as fluorescent lighting and small electric motors, and are designed to trip at currents between five and ten times their rated load.
Features and Benefits:
• Available in 1, 2 or 3 pole versions to suit your application needs
• DIN Rail mountable in any position to ensure easy installation
• Dependable protection for circuits due to instantaneous break time
• Indicator window allows clear visibility of contact state: red for closed, green for open
• Screw Terminals
• Thermal-magnetic tripping mechanism
• Can be used in extreme ambient conditions
• RohS compliant and fully recyclable, offering a more environmentally friendly solution
• DIN Rail mountable in any position to ensure easy installation
• Dependable protection for circuits due to instantaneous break time
• Indicator window allows clear visibility of contact state: red for closed, green for open
• Screw Terminals
• Thermal-magnetic tripping mechanism
• Can be used in extreme ambient conditions
• RohS compliant and fully recyclable, offering a more environmentally friendly solution
Certifications:
UL Recognised
CSA Certified
CE Marked
CCC Certified
VDE Certified
RoHS Compliant
CSA Certified
CE Marked
CCC Certified
VDE Certified
RoHS Compliant
Standards:
UL 1077
CSA C22.2 No. 235
EN 60947-2
GB 14048.2
CSA C22.2 No. 235
EN 60947-2
GB 14048.2
Allen Bradley MCB, 63A Maximum Current Rating, Type C Tripping - 1492-SPM2C630
Keep your industrial system safe from hazards by using this MCB from Rockwell Automation's Allen Bradley range. When it senses excess current, it quickly cuts off the power supply to the circuit, preventing damage to downstream equipment. Thanks to its type C characteristic, this unit trips at between 5 and 10 times its rated current. To reset it, simply flip the built-in toggle switch on the front. You can mount this MCB by snapping it onto a DIN rail, eliminating the need for complex tools.
• High maximum current rating of 63A to withstand heavy-duty equipment
• Resistant to shock and vibration to prevent false tripping
• IP20 rating indicates it's protected from objects more than 12mm in size
• Broad operating temperature range between -25°C and +55°C to withstand harsh environments
• Mountable in any position for flexible assembly
• Resistant to shock and vibration to prevent false tripping
• IP20 rating indicates it's protected from objects more than 12mm in size
• Broad operating temperature range between -25°C and +55°C to withstand harsh environments
• Mountable in any position for flexible assembly
Standards and Certifications
• VDE Certified
• UL Recognised
• CSA C22.2 No. 235
• EN 60947-2
• CCC Certified
• UL Recognised
• CSA C22.2 No. 235
• EN 60947-2
• CCC Certified
How durable is this MCB?
This MCB has a mechanical endurance rating of 20,000 operations, so you can be certain of its long service.
Allen Bradley MCBs
Related links
- Allen Bradley 1492 1492-SPM MCB 63A Curve D 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 10A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 16A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 4A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 40A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 20A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 32A Curve C 96V DC, 10 kA Breaking Capacity
- Allen Bradley 1492 1492-SPM MCB 2A Curve C 96V DC, 10 kA Breaking Capacity