ABB S403M MCB, 3P, 20A Curve D, 12V AC, 10 kA Breaking Capacity
- RS Stock No.:
- 140-597
- Mfr. Part No.:
- 2CCS573001R0201
- Brand:
- ABB
Subtotal (1 unit)*
£120.62
(exc. VAT)
£144.74
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 01 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £120.62 |
*price indicative
- RS Stock No.:
- 140-597
- Mfr. Part No.:
- 2CCS573001R0201
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 3 | |
| Current Rating | 20A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 12V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Series | S403M | |
| Circuit Breaker Type | MCB | |
| Width | 54mm | |
| Length | 75mm | |
| Mounting Style | DIN Rail | |
| Depth | 75mm | |
| Model Number | S403M-D20 | |
| Terminal Contact Type | Screw | |
| Application | Commercial, Industrial | |
Select all | ||
|---|---|---|
Brand ABB | ||
Number of Poles 3 | ||
Current Rating 20A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 12V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Series S403M | ||
Circuit Breaker Type MCB | ||
Width 54mm | ||
Length 75mm | ||
Mounting Style DIN Rail | ||
Depth 75mm | ||
Model Number S403M-D20 | ||
Terminal Contact Type Screw | ||
Application Commercial, Industrial | ||
- COO (Country of Origin):
- CH
ABB S403M Series MCB, 20A Current Rating, 3 Poles - 2CCS573001R0201
This is an MCB designed to provide reliable overcurrent protection in commercial and industrial settings. The S403M-D20 operates with a current rating of 20A and features a 3-pole configuration. Its thermal electromechanical tripping mechanism ensures effective overload and short circuit protection. This DIN Rail Circuit Breaker measures 54mm in width and 75mm in length, making it suitable for various circuit setups.
Features & Benefits
• Trip characteristics are compliant with Type D standards for high inrush currents
• Offers a breaking capacity of up to 10 kA, suitable for industrial applications
• Thermal and electromechanical mechanisms enhance reliability in diverse conditions
• Compact design allows easy installation on standard DIN rails
• Accommodates flexible and rigid connecting capacities for versatile wiring
• Indicator lights provide clear visibility of the circuit's status
• Offers a breaking capacity of up to 10 kA, suitable for industrial applications
• Thermal and electromechanical mechanisms enhance reliability in diverse conditions
• Compact design allows easy installation on standard DIN rails
• Accommodates flexible and rigid connecting capacities for versatile wiring
• Indicator lights provide clear visibility of the circuit's status
Applications
• Utilised for overload protection in commercial installations
• Effective in safeguarding industrial machines and equipment
• Used in critical power requiring dependable circuit protection
• Ideal for managing electrical systems in automated environments
• Effective in safeguarding industrial machines and equipment
• Used in critical power requiring dependable circuit protection
• Ideal for managing electrical systems in automated environments
How does the tripping mechanism function in this device?
The tripping mechanism utilises a combination of thermal and electromechanical methods. The thermal component provides delayed tripping for overloads, whereas the electromechanical aspect responds rapidly to short circuits, ensuring comprehensive protection.
What do the rated operational voltages mean for usage scenarios?
The rated operational voltages indicate that the device can function effectively between 12V and 440V AC. This range ensures its compatibility with various electrical systems, from low-voltage applications to standard industrial mains.
How can I confirm the breaking capacity for my specific application?
The breaking capacity of this circuit breaker is rated at 10 kA at both 230V and 400 V. This high capacity is suitable for demanding environments where short circuit conditions may occur, ensuring the safety of connected circuits.
What wiring specifications should be considered during installation?
Wiring should use screw terminals capable of accommodating flexible conductors of 0.75 to 25 mm² and rigid conductors of 0.75 to 35 mm². Adhering to these specifications will ensure secure connections and optimal electrical performance.
Related links
- ABB S403M MCB 20A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 10A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 50A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 16A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 6A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 32A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 40A Curve D 10 kA Breaking Capacity
- ABB S403M MCB 20A Curve C 12V DC, 15 kA Breaking Capacity