Rosemount 5300 Series Guided Wave Radar Level Radar, Top Mount, Polyurethane-covered Aluminium Body
- RS Stock No.:
- 892-9381
- Mfr. Part No.:
- 5301HA2S1V5AM01000SANAW2
- Brand:
- Rosemount
Subtotal (1 unit)*
£3,920.64
(exc. VAT)
£4,704.77
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 05 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £3,920.64 |
*price indicative
- RS Stock No.:
- 892-9381
- Mfr. Part No.:
- 5301HA2S1V5AM01000SANAW2
- Brand:
- Rosemount
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Rosemount | |
Device Type | Guided Wave Radar | |
Mounting Type | Top Mount | |
Body Material | Polyurethane-covered Aluminium | |
Cable Length | 10m | |
Minimum Operating Temperature | -15°C | |
Maximum Operating Temperature | +150°C | |
Maximum DC Voltage | 42.4V | |
Maximum Pressure | 40bar | |
Series | 5300 | |
Standards Met | ATEX, CSA, EAC, EU, FM, IE, IEC, IM, NCC, SBS, SBV, SDN, SIL, SIS, SLL | |
Select all | ||
---|---|---|
Brand Rosemount | ||
Device Type Guided Wave Radar | ||
Mounting Type Top Mount | ||
Body Material Polyurethane-covered Aluminium | ||
Cable Length 10m | ||
Minimum Operating Temperature -15°C | ||
Maximum Operating Temperature +150°C | ||
Maximum DC Voltage 42.4V | ||
Maximum Pressure 40bar | ||
Series 5300 | ||
Standards Met ATEX, CSA, EAC, EU, FM, IE, IEC, IM, NCC, SBS, SBV, SDN, SIL, SIS, SLL | ||
RoHS Status: Not Applicable
- COO (Country of Origin):
- GB
5301 Enhanced Guided Wave Radar
Emersons 5300 series of high performance guided wave transmitters are suitable for both level and interface measurement delivering accurate results with minimal maintenance and calibration requirements.
Utilising guided wave measurement technology the 5301 can be used in applications where both vapour and turbulence are present and does not require compensation for changes in temperature, density or pressure and can be installed in most level and liquid storage applications including those with small tanks, obstructions and difficult storage vessel geometry.
Utilising guided wave measurement technology the 5301 can be used in applications where both vapour and turbulence are present and does not require compensation for changes in temperature, density or pressure and can be installed in most level and liquid storage applications including those with small tanks, obstructions and difficult storage vessel geometry.
Features and Benefits
Unique Direct Switch Technology and Probe End Projection improve capability and reliability particularly in challenging applications
Single lead probe for long measuring ranges, obstructions and low dielectrics ensures reliability in more applications, such as viscous media
Smart Galvanic Interface results in a more stable microwave and EMI performance with minimized effects from outside disturbances
Heavy-duty unique hardware for extreme temperature and pressures with multiple layers of protection
EchoLogics and smart software functions provide enhanced ability to keep track of the surface and detect a full vessel situation
Third party approved for overfill prevention and Safety Integrated System SIL3 suitability
Electronics and cable connections in separate compartments provides safer handling and improved moisture protection
Online device verification and reliable detection of high level conditions with the verification reflector
Single lead probe for long measuring ranges, obstructions and low dielectrics ensures reliability in more applications, such as viscous media
Smart Galvanic Interface results in a more stable microwave and EMI performance with minimized effects from outside disturbances
Heavy-duty unique hardware for extreme temperature and pressures with multiple layers of protection
EchoLogics and smart software functions provide enhanced ability to keep track of the surface and detect a full vessel situation
Third party approved for overfill prevention and Safety Integrated System SIL3 suitability
Electronics and cable connections in separate compartments provides safer handling and improved moisture protection
Online device verification and reliable detection of high level conditions with the verification reflector
Related links
- Rosemount 3300 Series Guided Wave Radar Level Radar Polyurethane-covered Aluminium Body
- Vega Replacement 4mm Diameter Cable Probe for Use with Guided Wave Radar TDR Liquid Level Transmitter
- Flowline EchoWave Series Guided Radar Level Sensor Level Radar Aluminium Body
- Flowline EchoWave Series Guided Radar Level Transmitter Level Radar Aluminium Body
- Siemens SITRANS LR Series Radar Level Transmitter Level Transmitter Aluminium Body
- SICK Guided Radar Level Radar 4-20 mA Output Stainless Steel Body
- SICK Guided Radar Level Radar 4-20 mA Output PBT Body
- SICK LFP Cubic Series Guided Radar Level Radar Vertical, Plastic PBT Body