HARTING Heavy Duty Power Connector Insert, 10A, HAN Quintax Series Female, 4 Contacts
- RS Stock No.:
- 547-2012
- Distrelec Article No.:
- 300-78-605
- Mfr. Part No.:
- 09150043113
- Brand:
- HARTING
Bulk discount available
Subtotal (1 unit)*
£31.03
(exc. VAT)
£37.24
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 - 9 | £31.03 |
| 10 - 24 | £30.24 |
| 25 + | £29.50 |
*price indicative
- RS Stock No.:
- 547-2012
- Distrelec Article No.:
- 300-78-605
- Mfr. Part No.:
- 09150043113
- Brand:
- HARTING
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | HARTING | |
| Current Rating | 10A | |
| Product Type | Heavy Duty Power Connector Insert | |
| Series | HAN Quintax | |
| Sub Type | Insert | |
| Connector Gender | Female | |
| For Use With | Heavy Duty Power Connector | |
| Pole Format | 4 | |
| Number of Rows | 2 | |
| Voltage | 50V | |
| Mount Type | Cable | |
| Standards/Approvals | IEC 60664-1 | |
| Number of Contacts | 4 | |
| Minimum Wire Size mm² | 0.14mm² | |
| Orientation | Straight | |
| Contact Material | Polycarbonate | |
| Maximum Wire Size mm² | 2.5mm² | |
| Select all | ||
|---|---|---|
Brand HARTING | ||
Current Rating 10A | ||
Product Type Heavy Duty Power Connector Insert | ||
Series HAN Quintax | ||
Sub Type Insert | ||
Connector Gender Female | ||
For Use With Heavy Duty Power Connector | ||
Pole Format 4 | ||
Number of Rows 2 | ||
Voltage 50V | ||
Mount Type Cable | ||
Standards/Approvals IEC 60664-1 | ||
Number of Contacts 4 | ||
Minimum Wire Size mm² 0.14mm² | ||
Orientation Straight | ||
Contact Material Polycarbonate | ||
Maximum Wire Size mm² 2.5mm² | ||
Harting HAN Quintax Series Heavy Duty Power Connector Insert, 10A Current Rating, 50V Voltage - 9150043113
This heavy-duty power connector insert is a cable-mount female insert designed for industrial power connections. It provides a straight, 4-contact electrical Interface for low-voltage distribution within control cabinets, machinery harnesses and modular connector assemblies. Constructed for use where compact, rated connections are required, it pairs with matching heavy-duty housings to deliver routine power transmission in automated and electrical systems.
Features & Benefits
• Rated for continuous 10A current to support moderate loads
• Operates at a nominal 50V for low-voltage installations
• Four contacts arranged in two rows for Compact pole distribution
• Accepts conductors from 0.14 mm² to 2.5 mm² for wiring flexibility
• Contact surfaces formed from polycarbonate to reduce wear
• Cable-mount format simplifies in-line panel and harness routing
• Operates at a nominal 50V for low-voltage installations
• Four contacts arranged in two rows for Compact pole distribution
• Accepts conductors from 0.14 mm² to 2.5 mm² for wiring flexibility
• Contact surfaces formed from polycarbonate to reduce wear
• Cable-mount format simplifies in-line panel and harness routing
**Applications**
• Suitable for power distribution in control panels and switchgear
• Ideal for connection of motors and actuators in automation cells
• Used with modular heavy-duty housings for field-installed cabling
• Can be used for industrial machine-to-machine power links
• Used for temporary power links in testing and maintenance rigs
• Ideal for connection of motors and actuators in automation cells
• Used with modular heavy-duty housings for field-installed cabling
• Can be used for industrial machine-to-machine power links
• Used for temporary power links in testing and maintenance rigs
What insulation standards relate to the inserts electrical separation?
It conforms with IEC 60664-1 for required insulation coordination and clearance distances in low-voltage assemblies.
Which conductor sizes can be terminated reliably into the contacts?
Termination accommodates conductors from 0.14 mm² up to 2.5 mm², covering fine-stranded control conductors to thicker supply leads.
How is the insert oriented when installed in a cable assembly?
The insert is supplied in a straight orientation for in-line cable routing without angular offset.
What contact count and configuration does it provide for multi-pole circuits?
It provides four poles organised across two rows to support multi-conductor power circuits.
Related links
- HARTING Heavy Duty Power Connector Insert HAN Modular Series Female, 4 Contacts
- HARTING Heavy Duty Power Connector Module 4 Contacts
- HARTING Heavy Duty Power Connector Module HAN Modular Series Female, 4 Contacts
- HARTING Heavy Duty Power Connector Module HAN Modular Series Female, 4 Contacts
- HARTING Heavy Duty Power Connector Module HAN Modular Series Female, 4 Contacts
- HARTING Heavy Duty Power Connector Insert HAN Modular Series Male, 4 Contacts
- HARTING Heavy Duty Power Connector Module 4 Contacts
- HARTING Heavy Duty Power Connector Module HAN Modular Series Male, 4 Contacts