Megger DET4TC2 Earth Tester, 200000Ω CAT IV 100 V RS Calibration
- RS Stock No.:
- 521-718
- Mfr. Part No.:
- 1000-345
- Brand:
- Megger
Subtotal (1 unit)*
£1,471.04
(exc. VAT)
£1,765.25
(inc. VAT)
FREE delivery for orders over £50.00
In Stock
- 3 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £1,471.04 |
*price indicative
- RS Stock No.:
- 521-718
- Mfr. Part No.:
- 1000-345
- Brand:
- Megger
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Megger | |
Calibrated | RSCAL | |
Absolute Maximum Resistance Measurement | 200000Ω | |
Best Accuracy | ±2% + 3 Digits | |
Display Type | LCD | |
Measurement Type | 4 Terminal Earth Resistance, Soil Resistance | |
Safety Category | CAT IV 100 V | |
Battery Life | 3 h | |
Battery Type | AA | |
Power Source | Battery | |
Weight | 1kg | |
Height | 148mm | |
Includes | Calibration Certificate, Case, Spike, Test Lead | |
Length | 203mm | |
Maximum Operating Temperature | +55°C | |
Minimum Operating Temperature | -15°C | |
Model Number p | DET4TC2 | |
Width | 78mm | |
Select all | ||
---|---|---|
Brand Megger | ||
Calibrated RSCAL | ||
Absolute Maximum Resistance Measurement 200000Ω | ||
Best Accuracy ±2% + 3 Digits | ||
Display Type LCD | ||
Measurement Type 4 Terminal Earth Resistance, Soil Resistance | ||
Safety Category CAT IV 100 V | ||
Battery Life 3 h | ||
Battery Type AA | ||
Power Source Battery | ||
Weight 1kg | ||
Height 148mm | ||
Includes Calibration Certificate, Case, Spike, Test Lead | ||
Length 203mm | ||
Maximum Operating Temperature +55°C | ||
Minimum Operating Temperature -15°C | ||
Model Number p DET4TC2 | ||
Width 78mm | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
DET4TC 4 Pole Earth Tester
4 pole earth tester for measuring soil resistivity and resistance of earth rods and associated installations. Supplied in a hard carry case together with auxiliary stakes and cables.,An ICLAMP selective clamp is available separately, and when used with the DET4TC allows the testing of an earth rod without the need for disconnection from the system.,A VCLAMP is also available separately, which when used in conjunction with ICLAMP allows stakeless measurements to be made in situations where driving auxiliary stakes is not practical.
Resistance range 0.01 to 20000 ohms auto ranging
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and VCLAMP)
Earth current range (requires ICLAMP)
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and VCLAMP)
Earth current range (requires ICLAMP)
Standards
EN61010-1 CAT IV 100V
Supplied with
4 earth test stakes, 4 connection leads, 8 x AA alkaline batteries, hard carry case, quick start guides, user guide on CD
Megger Earth Tester, 1 to 100V Ground Noise Voltage Measuring Range, 0.01 to 200kΩ Resistance Measuring Range - DET4 Series - 1000-345
Use this digital earth tester from Megger to check the grounding of your electrical circuits. It comes with test leads, stakes and terminal adaptors, making it a breeze to measure ground resistivity using two, three or four-pole methods, stakeless reading or the Attached Rod Technique (ART). Its compact size of 203 (L) x 148 (W) x 78mm (H) means it's portable for fuss-free testing while you're on the go. This hardy device can beat the highs and lows of harsh work environments, thanks to its broad operating temperature range between -15°C and +55°C.
Features & Benefits
• IP54 rating indicates partial dust resistance and full protection against water sprays
• Test frequency options of 94, 105, 111 and 128Hz for greater functionality
• Test frequency options of 94, 105, 111 and 128Hz for greater functionality
Applications
• Telecommunications equipment
• Domestic wiring systems
• Power distribution lines
• Electrical appliances
• Domestic wiring systems
• Power distribution lines
• Electrical appliances
How accurate is this earth tester?
This tester has a resistance accuracy rating of 2% ±3 digits for two, three and four-pole functions, 5% ±3 digits for the ART method and 7% ±3 digits for stakeless measurements, so you can count on precise readings.
Related links
- Megger DET4TC2 Earth Tester, 200kΩ CAT IV 100 V
- Megger DET4TCR2 Earth Tester, 200000Ω CAT IV 100 V RS Calibration
- Megger DET3TC Earth Tester, 2000Ω CAT IV 100 V RS Calibration
- Megger DET14C Earth Tester, 1500Ω CAT IV 600 V RS Calibration
- Megger DET4TD2 Earth Tester Kit, 20kΩ CAT IV 100 V
- Megger DET4TCR2 Earth Tester, 200kΩ CAT IV 100 V
- Megger DET3TC Earth Tester, 2kΩ CAT IV 100 V
- Megger DET4TD2 Earth Tester Kit RS Calibration