Omron S8TS Switched Mode DIN Rail Power Supply, 85 → 264V ac ac Input, 12V dc dc Output, 2.5A Output, 30W
- RS Stock No.:
- 408-4939
- Mfr. Part No.:
- S8TS-03012-E1
- Brand:
- Omron
Subtotal (1 unit)*
£171.59
(exc. VAT)
£205.91
(inc. VAT)
FREE delivery for orders over £50.00
Temporarily out of stock
- Shipping from 05 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
---|---|
1 + | £171.59 |
*price indicative
- RS Stock No.:
- 408-4939
- Mfr. Part No.:
- S8TS-03012-E1
- Brand:
- Omron
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | Omron | |
Series | S8TS | |
Type | Switched Mode | |
Electrical Phase | 1 | |
AC or DC Input Voltage | ac | |
Number of Outputs | 1 | |
Input Voltage | 85 → 264V ac | |
AC or DC Output Voltage | dc | |
Output Voltage | 12V dc | |
Output Current | 2.5A | |
Dimensions | 120 x 48 x 128.1mm | |
Height | 120mm | |
Depth | 120mm | |
Width | 48mm | |
Load Regulation | ±2% | |
Mounting Type | DIN Rail Mount | |
MTBF | 250000h | |
Maximum Temperature | +40°C | |
Ripple And Noise | ±2% | |
Efficiency | 73% | |
Minimum Temperature | 0°C | |
Select all | ||
---|---|---|
Brand Omron | ||
Series S8TS | ||
Type Switched Mode | ||
Electrical Phase 1 | ||
AC or DC Input Voltage ac | ||
Number of Outputs 1 | ||
Input Voltage 85 → 264V ac | ||
AC or DC Output Voltage dc | ||
Output Voltage 12V dc | ||
Output Current 2.5A | ||
Dimensions 120 x 48 x 128.1mm | ||
Height 120mm | ||
Depth 120mm | ||
Width 48mm | ||
Load Regulation ±2% | ||
Mounting Type DIN Rail Mount | ||
MTBF 250000h | ||
Maximum Temperature +40°C | ||
Ripple And Noise ±2% | ||
Efficiency 73% | ||
Minimum Temperature 0°C | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
25W to 60W S8TS Series
Range Features:
Modular units which can be connected together (4 units max. on 24Vdc and 12Vdc, 2 units on 5Vdc)
Up to 10A max. output (+1 unit for redundancy -12V and 24V units only)
On board (bus style) connections for AC/DC (same DC voltages only)
DC outputs can be combined or used separately
DC voltage low indication and alarm on each unit
Overload/Over-voltage protection
EMI to EN50081-1, FCC-B
Under-voltage detection and LED indicator
Up to 10A max. output (+1 unit for redundancy -12V and 24V units only)
On board (bus style) connections for AC/DC (same DC voltages only)
DC outputs can be combined or used separately
DC voltage low indication and alarm on each unit
Overload/Over-voltage protection
EMI to EN50081-1, FCC-B
Under-voltage detection and LED indicator
Standards
EN60950, UL1950, CSA22.2-14-950.
Approvals
UL Recognised; UL Recognised for Canada
Part Number S8TS-03012-E1
The S8TS Switch mode, Din Rail mounted power supply is a covered type, screw terminal basic block with Bus Line connectors. S8TS-03012-E1 has a power rating of 30 W and an output voltage of 12 V dc plus a rated input voltage of 100 V ac to 240 V ac. This Standard undervoltage alarm model is natural air cooling.
Features and Benefits.
• Covered type power supply Basic block
• Screw terminal
• With Bus line connector terminals – Bus line not included
• DIN Rail Mounted
• Green output indicators
• Natural air cooling
• Power rating 30 W
• Output voltage 12 V dc
• Input voltage 100 V ac to 240 V ac
• Rated output current 2.5 A
• Harmonic current emissions
• Efficiency 73% min.
• Overload and over voltage protection
• Under-voltage alarm output – open collector, 30 V dc, 50 mA
• Weight 450g
Safety and Storage.
Do not use an inverter output for the power supply. Mount the power supply using a DIN Rail and secure correctly ensuring limited vibration and shock resistance. Install the power supply away from contactors and other devices. Keep the power supply away from strong high frequency noise and surge.
Vibration resistance 10 Hz to 55 Hz. 0.375 0.26 mm single amplitude in each 3 directions for 2 hours.
Shock resistance 150 m/s**2 in each 6 directions 3 times.
Approvals
UL Recognised; UL Recognised for Canada
Standards
UL 508 (Listing; class 2: Per UL 1310), 1950, 1604 (class I, division 2, groups A, B, C, D hazardous locations)
cUL: CSA C22.2 No 14, No.213 (class I, Division 2, groups A, B, C, D hazardous locations), No. 950 (class 2) ( class 2 approval does not apply to parallel operation)
EN/VDE: EN50178 (=VDE0160), 60950 (VDE0806)
cUL: CSA C22.2 No 14, No.213 (class I, Division 2, groups A, B, C, D hazardous locations), No. 950 (class 2) ( class 2 approval does not apply to parallel operation)
EN/VDE: EN50178 (=VDE0160), 60950 (VDE0806)
Related links
- Omron S8VS Switched Mode DIN Rail Power Supply 12V dc dc Output 30W
- Omron S8TS Switched Mode DIN Rail Power Supply 5V dc dc Output 25W
- Omron S8TS DIN Rail Power Supply 24V dc dc Output 60W
- TRACOPOWER TBL Switched Mode DIN Rail Power Supply 12V dc dc Output 30W
- Chinfa DRAN30 Switched Mode DIN Rail Power Supply 12V dc dc Output 30W
- TDK-Lambda DRB Switched Mode DIN Rail Power Supply 12V dc dc Output 30W
- RS PRO Switched Mode DIN Rail Power Supply 12V dc dc Output 30W
- ELC ALE Switched Mode DIN Rail Power Supply 12V dc dc Output 30W