Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | ±12V dc | |
Input Voltage Range | 5.5 → 9 V dc | |
Power Rating | 10W | |
Input Voltage Nominal | 5 V dc | |
Output Current | ±416mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 2 | |
Output Voltage Adjustment Range | ±10.8 V dc, ±13.2V dc | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Length | 31.8mm | |
Width | 20.3mm | |
Depth | 10.4mm | |
Series | REM10 | |
Load Regulation | ±1% | |
Efficiency | 85.5% | |
Maximum Temperature | +105°C | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A34, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A34, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Medical Approved | Yes | |
Minimum Temperature | -40°C | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage ±12V dc | ||
Input Voltage Range 5.5 → 9 V dc | ||
Power Rating 10W | ||
Input Voltage Nominal 5 V dc | ||
Output Current ±416mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 2 | ||
Output Voltage Adjustment Range ±10.8 V dc, ±13.2V dc | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Length 31.8mm | ||
Width 20.3mm | ||
Depth 10.4mm | ||
Series REM10 | ||
Load Regulation ±1% | ||
Efficiency 85.5% | ||
Maximum Temperature +105°C | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A34, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A34, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Medical Approved Yes | ||
Minimum Temperature -40°C | ||
Related links
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp
- Recom REM10 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM10 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM10 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C