XP Power RDL100 DC-DC Converter, 15V dc/ 6.7A Output, 66 → 160 V dc Input, 100W, Through Hole, +100°C Max Temp
- RS Stock No.:
- 174-4630
- Mfr. Part No.:
- RDL100110S15
- Brand:
- XP Power
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS Stock No.:
- 174-4630
- Mfr. Part No.:
- RDL100110S15
- Brand:
- XP Power
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
---|---|---|
Brand | XP Power | |
Output Voltage | 15V dc | |
Input Voltage Range | 66 → 160 V dc | |
Power Rating | 100W | |
Input Voltage Nominal | 110 V dc | |
Output Current | 6.7A | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Package | Half Brick | |
Isolation Voltage | 3kV dc | |
Length | 61mm | |
Depth | 12.7mm | |
Width | 57.9mm | |
Railway Approved | Yes | |
Series | RDL100 | |
Load Regulation | ±0.2% | |
Minimum Temperature | -40°C | |
Maximum Temperature | +100°C | |
Standards Met | cUL 60950-1, EN 50121-3-2, EN 50155, En 50155, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, MIL-HDBK-217F, UL | |
Select all | ||
---|---|---|
Brand XP Power | ||
Output Voltage 15V dc | ||
Input Voltage Range 66 → 160 V dc | ||
Power Rating 100W | ||
Input Voltage Nominal 110 V dc | ||
Output Current 6.7A | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Package Half Brick | ||
Isolation Voltage 3kV dc | ||
Length 61mm | ||
Depth 12.7mm | ||
Width 57.9mm | ||
Railway Approved Yes | ||
Series RDL100 | ||
Load Regulation ±0.2% | ||
Minimum Temperature -40°C | ||
Maximum Temperature +100°C | ||
Standards Met cUL 60950-1, EN 50121-3-2, EN 50155, En 50155, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, MIL-HDBK-217F, UL | ||
Wide3:1 Input Range
Covers 110VDC Nominal Input for Rail Applications
Single Output
Industry Standard HalfBrick
-40°C to +100°C Operation
Output Trim ±10%
Remote On/Off
3 Year Warranty
Covers 110VDC Nominal Input for Rail Applications
Single Output
Industry Standard HalfBrick
-40°C to +100°C Operation
Output Trim ±10%
Remote On/Off
3 Year Warranty
Related links
- XP Power RDL100 DC-DC Converter 66 → 160 V dc Input Through Hole, +100°C Max Temp
- XP Power RDL100 DC-DC Converter 66 → 160 V dc Input Through Hole, +100°C Max Temp
- XP Power RDL100 DC-DC Converter 66 → 160 V dc Input Through Hole, +100°C Max Temp
- Cosel DHS DC-DC Converter 60 → 160 V dc Input PCB Mount, +100°C Max Temp -40°C
- TDK-Lambda CN-A DC-DC Converter 60 → 160 V dc Input Through Hole, +100°C Max Temp
- TDK-Lambda CN B110 DC-DC Converter 43 To 160 V dc Input Through Hole, +100°C Max Temp
- XP Power QSB100 DC-DC Converter 9 → 36 V dc Input PCB Mount, +100°C Max Temp -40°C