Recom REM6 DC-DC Converter, ±15V dc/ ±200mA Output, 9 → 18 V dc Input, 6W, Through Hole, +105°C Max Temp -40°C
- RS Stock No.:
- 166-6516
- Mfr. Part No.:
- REM6-1215D/A
- Brand:
- Recom
Subtotal (1 tube of 7 units)*
£433.33
(exc. VAT)
£520.00
(inc. VAT)
FREE delivery for orders over £50.00
- Shipping from 01 December 2025
Tube(s) | Per Tube | Per unit* |
---|---|---|
1 + | £433.33 | £61.904 |
*price indicative
- RS Stock No.:
- 166-6516
- Mfr. Part No.:
- REM6-1215D/A
- Brand:
- Recom
Select all | Attribute | Value |
---|---|---|
Brand | Recom | |
Output Voltage | ±15V dc | |
Input Voltage Range | 9 → 18 V dc | |
Power Rating | 6W | |
Input Voltage Nominal | 12 V dc | |
Output Current | ±200mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 2 | |
Output Voltage Adjustment Range | ±13.5 V dc, ±16.5V dc | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Width | 20.3mm | |
Length | 31.8mm | |
Depth | 10.4mm | |
Series | REM6 | |
Load Regulation | ±1% | |
Maximum Temperature | +105°C | |
Efficiency | 87 %, 87.5 %, 88 %, 88.5 % | |
Minimum Temperature | -40°C | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A25, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A25, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Select all | ||
---|---|---|
Brand Recom | ||
Output Voltage ±15V dc | ||
Input Voltage Range 9 → 18 V dc | ||
Power Rating 6W | ||
Input Voltage Nominal 12 V dc | ||
Output Current ±200mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 2 | ||
Output Voltage Adjustment Range ±13.5 V dc, ±16.5V dc | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Width 20.3mm | ||
Length 31.8mm | ||
Depth 10.4mm | ||
Series REM6 | ||
Load Regulation ±1% | ||
Maximum Temperature +105°C | ||
Efficiency 87 %, 87.5 %, 88 %, 88.5 % | ||
Minimum Temperature -40°C | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A25, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A25, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Related links
- Recom REM6 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C Max Temp -40°C Min
- Recom REM6 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C
- Recom REM6 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C Max Temp -40°C